Laserfiche WebLink
�PaUIN cG Environmental Health Department <br /> SAN 10 A Q U I N <br /> 0 <br /> dd <br /> F ` COUNTY -- Kasey Foley , REHS , Interim Director <br /> C'q4 /F906 Greatness grows here . PROGRAM COORDINATORS <br /> Robert McClellon , REHS <br /> Jeff Carruesco , REHS , RDI <br /> Willy Ng , REHS <br /> Muniappa Naidu , REHS <br /> Michael Kith , REHS <br /> Melissa Nissim , REHS <br /> March 5 , 2020 <br /> Megan Mitchell <br /> Elite IV Contractors <br /> 2535 Wigwam Dr . <br /> Stockton , CA 95205 <br /> Re : Central Gas SR0081568 , amended <br /> 2358 E . Waterloo Rd . , Stockton , CA 95205 <br /> The San Joaquin County Environmental Health Department ( EHD) has completed the review of the <br /> application for a permit to replace dispensers , install conversion frames , and replace the 87 drop tube <br /> on the underground storage tank ( UST) system at the above noted address . The permit has been <br /> approved with the following conditions : <br /> 1 . Contact the local fire department and the San Joaquin Valley Air Pollution Control District for <br /> any applicable permits and requirements . <br /> 2 . Any changes in information and scope of work must be submitted to EHD for approval prior to <br /> commencing work . All new addenda supersede the previous ones . <br /> 3 . Provide written notification to ust (atslgov . org or contact Stacy Rivera at (209 ) 468-3440 to <br /> arrange the following inspection appointments (a 48 - hour notice is required for inspection <br /> appointments ) . Please be aware that inspections for emergency work must be scheduled <br /> within five days of permit approval . <br /> a . Verification of the dispenser footprints contained by the under dispenser containment <br /> ( UDCs ) . <br /> b . Visual inspection of the piping within the dispensers for any leaks . <br /> c . Overfill prevention verification : Measurement of drop tubes to verify 95 % tank volume shut <br /> off. Verification of flapper functionality . Ensure that all pertinent tank charts and <br /> calculations are available for review at the time of inspection . <br /> d . Verification that ball float (s) , if installed , do not interfere with the installed flapper valve . <br /> e . If concrete will be broken near the UDCs , piping , tanks , or sumps , a secondary containment <br /> test must be performed on the affected components once concrete is poured , in <br /> accordance with the manufacturer' s guidelines . <br /> 4 . Any individual performing the work of a service technician must meet the following <br /> qualifications : <br /> a . Possess or be employed by a person who possesses one of several permissible valid , <br /> current contractor' s licenses issued by the Contractors State License Board ( may be issued <br /> to the installation company) , or a Tank Tester' s license issued to the individual by the State <br /> Water Board , and <br /> b . Possess or work under the direct and personal supervision of an individual physically <br /> present at the work site who possesses a valid , current California UST Service Technician <br /> certificate issued by the International Code Council ( ICC ) , and <br /> 1868 E . Hazelton Avenue I Stockton , California 95205 1 T 209 468-3420 1 F 209 464 -0138 1 www . sjgov . org /ehd <br />