Laserfiche WebLink
S ` ` , J O A Q U I N Environmental Health Department <br /> C0U "ATY <br /> Swimming Pool Official Inspection Report <br /> Facility Name and Address: WESTPOINTE APARTMENTS SE POOL, 6465 N WEST LN, STOCKTON 95210 <br /> #9 Ladders and Handrails <br /> OBSERVATIONS:The North side handrails isloose. Secure or tighten this handrail within one week. <br /> CALCODE DESCRIPTION:A means of entry and exit shall be provided at both the shallow and deep end of the pool. Ladders and <br /> handrails shall be corrosion resistant and shall be rigidly installed.At least one handrail shall extend from the deck to not less than a point <br /> above the top of the lowest step. Handrails shall be installed between 28 to 36 inches above the steps and deck. (CBC 311 1B)Pool <br /> operator shall keep ladders and handrails well maintained. (CCR 65535) <br /> #18 Pool Shell and Tile <br /> OBSERVATIONS:There are cracked copings observed around the depth marker 4'/2 and 5. Patch these cracked copings <br /> within one month. <br /> CALCODE DESCRIPTION:Pool shells shall be white and have a smooth waterproof interior finish that will withstand repeated brushing, <br /> and scrubbing.A spa pool may be finished in a light color other than white when approved by the enforcement agency. (CBC 31086) <br /> #22 Skimmer Assembly <br /> OBSERVATIONS:There are no float and weir observed in the skimmer(East side). Provide within one week. <br /> There is no weir observed in the skimmer(South side). Provide within one week. <br /> The screen basket is not removable in the skimmer(South side). Repair this skimmer opening so the screen basket is <br /> removable, cleanable and accessible. Correct by May, 2021. <br /> CALCODE DESCRIPTION:Pool shall be equipped to provide continuous skimming of the pool water. All parts of the skimmer shall be <br /> maintained in accordance with manufacturer specifications. (CBC 31368) <br /> #36 Pressure and Vacuum Gauges <br /> OBSERVATIONS:The effluent pressure gauge is not functional. Replace this pressure gauge within one week. <br /> CALCODE DESCRIPTION:Pressure and vacuum gauges shall be provided for each pump system. (CBC 31258) <br /> OVERALL INSPECTION NOTES AND COMMENTS <br /> OBSERVATIONS <br /> Flow rate: 90 gpm Chlorine: 5.6 ppm Temp: ° F <br /> Cyanuric acid: 0 ppm pH: 7.2 Combined chlorine: 0 ppm <br /> NOTES <br /> FA0007459 PR0360578 SCO01 06/09/2020 <br /> EHD 36-01 Rev.06/30/15 Page 2 of 3 Swimming Pool OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />