Laserfiche WebLink
S ` ` , J O A Q U I N Environmental Health Department <br /> C0U "ATY <br /> Swimming Pool Official Inspection Report <br /> Facility Name and Address: WESTPOINTE APARTMENTS NE SPA, 6465 N WEST LN, STOCKTON 95210 <br /> #9 Ladders and Handrails <br /> OBSERVATIONS:The handrail is loose. Secure or tighten this handrail within one week. <br /> CALCODE DESCRIPTION:A means of entry and exit shall be provided at both the shallow and deep end of the pool. Ladders and <br /> handrails shall be corrosion resistant and shall be rigidly installed.At least one handrail shall extend from the deck to not less than a point <br /> above the top of the lowest step. Handrails shall be installed between 28 to 36 inches above the steps and deck. (CBC 3111 B)Pool <br /> operator shall keep ladders and handrails well maintained. (CCR 65535) <br /> #18 Pool Shell and Tile <br /> OBSERVATIONS:There are crack observed near the mouth of the skimmer. Repair or patch these damages before May, <br /> 2021. <br /> CALCODE DESCRIPTION:Pool shells shall be white and have a smooth waterproof interior finish that will withstand repeated brushing, <br /> and scrubbing.A spa pool may be finished in a light color other than white when approved by the enforcement agency. (CBC 3108B) <br /> #22 Skimmer Assembly <br /> OBSERVATIONS:No float assembly and check valve observed. Provide these components within one week. <br /> CALCODE DESCRIPTION:Pool shall be equipped to provide continuous skimming of the pool water. All parts of the skimmer shall be <br /> maintained in accordance with manufacturer specifications. (CBC 31368) <br /> #27 Pool Equipment Room <br /> OBSERVATIONS:Overgrown vegetation observed in this spa equipment room. Clean and maintain this area clean and <br /> accessible within a week. <br /> CALCODE DESCRIPTION:Pool operator shall keep ancillary facilities well maintained. (CCR 65535)All filters, valves,pumps,strainers <br /> and equipment shall be readily accessible for repair and replacement. (CBC 3123B) <br /> #30 Pool Equipment and Plumbing Maintained <br /> OBSERVATIONS:There is leakage observed from heater. Repair this leakage within one month. <br /> CALCODE DESCRIPTION:All equipment related to pool operations shall be installed and maintained in accordance with manufacturer's <br /> specifications and shall comply with applicable requirements established by applicable NSF/ANSI-50 performance standards. (CBC <br /> 3123B) <br /> OVERALL INSPECTION NOTES AND COMMENTS <br /> OBSERVATIONS <br /> Flow rate: 70 gpm Chlorine: 5.8 ppm Temp: 70.00 ° F <br /> Cyanuric acid: 0 ppm pH: 7.4 Combined chlorine: 0 ppm <br /> NOTES <br /> FA0002425 PR0360594 SCO01 06/09/2020 <br /> EHD 36-01 Rev.06/30/15 Page 2 of 3 Swimming Pool OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />