Laserfiche WebLink
S ` ` , J O A Q U I N Environmental Health Department <br /> C0U "ATY <br /> Swimming Pool Official Inspection Report <br /> Facility Name and Address: RED ROOF INN, 1707 W FREMONT ST, STOCKTON 95203 <br /> #4 Safety Equipment <br /> OBSERVATIONS:Lack of life ring with rope. Provide immediately. Length of rope shall be pools width. <br /> CALCODE DESCRIPTION:Safety equipment shall be provided, maintained, readily visible, and available for use.Pools shall have at <br /> minimum one 12 foot fixed-length rescue pole with a permanently attached body hook and one 17-inch life ring with an attached throw <br /> rope. Throw rope shall be of sufficient length to span the maximum width of the pool and shall be stored to prevent kinking or fouling. <br /> (CCR 65540) <br /> #13 Cyanuric Acid Concentration <br /> OBSERVATIONS:CYA level is over 100 ppm (repeat violation). Pool shall be drained so that level is under 100 ppm. <br /> CALCODE DESCRIPTION:Pool operator shall maintain cyanuric acid concentration between 0.0 ppm and 100 ppm. (CCR 65530) <br /> #17 Cleanliness of Pool <br /> OBSERVATIONS:Pool is currently closed. Clean shell and deck before it reopens. <br /> CALCODE DESCRIPTION:Pool operator shall maintain clean pool water while the pool is in use and shall not allow debris to accumulate <br /> in the pool. Pool operator shall clean the bottom, sides,and other surfaces of the pool as often as necessary to keep pool surfaces clean <br /> and free of slime and algae. (CCR 65533) <br /> #22 Skimmer Assembly <br /> OBSERVATIONS:Shallow skimmer lacks weir door. Both skimmers lack check valves. (repeat violation). Provide all <br /> equipment by 1 week. <br /> CALCODE DESCRIPTION:Pool shall be equipped to provide continuous skimming of the pool water. All parts of the skimmer shall be <br /> maintained in accordance with manufacturer specifications. (CBC 31366) <br /> #29 Recirculation System Operation <br /> OBSERVATIONS:Pump is not running. Repair immediately for proper water circulation. <br /> CALCODE DESCRIPTION:Recirculation system shall be in operation whenever the pool is available for use and additional times as <br /> needed to maintain clear pool water. (CCR 65525) <br /> OVERALL INSPECTION NOTES AND COMMENTS <br /> OBSERVATIONS <br /> Flow rate: 0 gpm Chlorine: 3.4 ppm Temp: ° F <br /> Cyanuric acid: Over 100 ppm pH: 7.8 Combined chlorine: 0.2 ppm <br /> NOTES <br /> FA0001804 PR0360046 SCO01 06/08/2020 <br /> EHD 36-01 Rev.06/30/15 Page 2 of 3 Swimming Pool OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />