Laserfiche WebLink
SAN <br /> ` , J O A Q U I ` , Environmental Health Department <br /> COUNTY— AMENDED <br /> TD 4-29-19 <br /> RCRA Large Quantity Hazardous Waste Generator Inspection Report <br /> Facility Name: Facility Address: Date: <br /> SUMIDEN WIRE PRODUCTS CORPORATION 1 1412 EL PINAL DR, STOCKTON April 23, 2019 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 303 CCR 66265.33 Failed to maintain all communication or alarm systems, spill control, or decontamination equipment. <br /> There were a variety of secondary containments and secondary containment pallets all contained some type of oily <br /> sludge,water, or unknown liquid inside. <br /> -Secondary containments for totes near the oil storage building (bone yard)contained oily sludge inside. <br /> -Secondary containments for oil product that was stored inside of the oil storage building contained an oily <br /> substance. <br /> -Secondary containments at the used oil storage location contained oily sludge/water at the used drums of oil <br /> storage area. <br /> -Secondary containment pallet for a tote of phosphoric acid solution containing liquid inside. <br /> -Secondary containment pallet for compressor condensate and oily water had oily residue inside. <br /> All facility communications or alarm systems,fire protection equipment, spill control equipment, and decontamination <br /> equipment,where required, shall be tested and maintained as necessary to assure its proper operation in time of <br /> emergency. Immediately begin this practice. <br /> Immediately clean out all secondary containment and place waste in hazardous waste containers and maintain <br /> secondary containments as clean and dry. <br /> This is a repeat violation, Class II. <br /> 403 CCR 66265.173 Failed to keep hazardous waste containers closed except when adding or removing hazardous <br /> waste. <br /> -A container of compressor condensate to be disposed of as hazardous waste did not have a lid. <br /> All hazardous waste containers shall be closed at all times except when adding or removing waste. Immediately close <br /> these containers and ensure all hazardous waste containers are closed when not adding or removing waste. <br /> This is a minor violation. <br /> 406 CCR 66261.7 Contaminated container not marked with date emptied or managed within one year of being emptied. <br /> The following containers were found empty, but not marked empty with date emptied: <br /> -(1)empty container of POSCA Boiler treatment not marked with date emptied, stored inside of the oil storage <br /> building (bone yard)fence. <br /> -(1)empty Blue 55-gallon drum in the epoxy department <br /> -(1)empty 55-gallon container of ChemTreat BL8700 Boiler Water Treatment <br /> Containers larger than five gallons that previously held a hazardous material shall be marked with the date they were <br /> emptied and managed within one year of being emptied. Immediately mark and manage all empty containers per this <br /> section. <br /> This is a repeat violation, Class II. <br /> FA0001479 PR0220094 SCO01 04/23/2019 <br /> EHD 22-03 Rev.09/27/2018 Page 8 of 12 RCRA Large Quantity Hazardous Waste Generator OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />