Laserfiche WebLink
Waste Evaluation & Testing Summary <br /> Metal Wastes from Cutting and Grinding ( Sample from RTS Packaging - Stockton , CA) <br /> TTLC ( ppm ) STLC ( ppm ) TCLP ( ppm ) <br /> Compound/Substances EPA Waste code 2 Regulatory Regulatory s Regulatory <br /> Result Level' Result Level' Result Level <br /> Antimony None/CA Only < 40 500 not required 15 NA <br /> Arsenic D004 < 40 500 not required 5 < 0 . 10 5 <br /> Barium D005 < 10 10, 000 not required 100 0. 195 100 <br /> Beryllium None/CA Only < 4 75 not required 0. 75 NA <br /> Cadmium D006 < 10 100 not required 1 < 0 . 10 1 <br /> Chromium and/or chromium ( III ) compounds D007 800 21500 not required 5 < 0 . 10 5 <br /> Chromium (VI) compounds D007 NT 500 not required 5 NT <br /> Cobalt None/CA Only 63 81000 not required 80 NA <br /> Copper None/CA Only 1630 21500 not required 25 NA <br /> Lead D008 35 . 2 11000 not required 5 < 0. 10 5 <br /> Mercury D009 < 0. 03 20 not required 0 . 2 < 0. 01 0. 2 <br /> Molybdenum and/or molybdenum compounds None/CA Only 165 3 , 500 not required 350 NA <br /> Nickel and/or nickel compounds None/CA Only 707 21000 not required 20 NA <br /> Selenium D010 < 40 100 not required 1 < 0. 10 1 <br /> Silver D011 < 20 500 not required 5 < 0. 10 5 <br /> Thallium and/or thallium compounds None/CA Only < 40 700 not required 7 NA <br /> Vanadium and/or vanadium compounds None/CA Only 133 27400 not required 24 NA <br /> Zinc None/CA Only 100 52000 not required 250 NA <br /> Note 1 : 22 CCR § 66261 .24 <br /> Note 2: Pace Analytical Sample Results, L1122870, METAL FILINGS 07232019, 8/1 /19 <br /> Note 3: Pace Analytical Sample Results, L1125610, METAL FILINGS 072320, 8/9/19 <br /> NT = not tested ; NA = Not Applicable <br />