BATCH QC REPORT: Definitions and Terms <br /> Accuracy The ability of a procedure to determine the"true"concentration of an analyte <br /> Precision The reproducibility of a procedure demonstrated by the agreement between <br /> analyses performed on either duplicates of the same sample or a pair of <br /> duplicate spikes <br /> Batch A group of samples analyzed sequentially using the same calibration curve, <br /> reagents,and instrument <br /> Laboratory Laboratory reagent water spiked with known compounds and subjected to the <br /> Control Standard same procedures as the samples. The LCS thus indicates the accuracy of the <br /> (LCS) analytical method and, because it is prepared from a different source than the <br /> standard used to calibrate the instrument,it also serves to double-check the <br /> calibration <br /> Matrix QC Quality control tests performed on actual client samples. For most inorganic <br /> analyses,the laboratory uses a pair of duplicate samples and a spiked sample. <br /> For most organic analyses, the laboratory uses a pair of spiked samples <br /> (duplicate spikes) <br /> LC Result Laboratory result of an LCS analysis <br /> LT Result Expected result,or true value,of the LCS analysis <br /> R1, R2 Result: Result of the analysis of replicate aliquots of a sample,with R1 indicating the <br /> first analysis of the sample and R2 its corresponding duplicate; used to <br /> determine precision <br /> S1, S2 Result Result of the analysis of replicate spiked aliquots,with S 1 indicating one <br /> spike of the sample and S2 the second spike; used to determine precision and <br /> accuracy <br /> R Bar Result The average of replicate analysis results <br /> S Bar Result: The average of spike analysis results <br /> True value The theoretical,or expected,result of a spike sample analysis <br /> Percent The percentage of analyte recovered. <br /> Recovery For LCS, the percent recovery calculation is: LC+LT x 100 <br /> For spike recoveries, the percent recovery calculatiion is: <br /> (S Bar- Sample Concentration) X100 <br /> Spike Amount <br /> Relative Percent Calculated using one of the following: <br /> Difference(RPD) (RI - R2) x 100 (SI - S2) x 100 <br /> (R 1 + R2) +2 (S 1 +S2)+ 2 <br /> Blank Result The result of the analysis of a method blank,which is reagent water that is <br /> analysed using the same reagents, instruments and procedures as the samples <br /> in a batch; used to determine laboratory contamination <br /> Reporting Detec- BCA-assigned limit based on—but not the same as—method detection limits <br /> tion Limit(RDL) (MDLs)determined using EPA guidelines <br /> 13 (:,tnnlvlical <br />