Laserfiche WebLink
KLEINFELDER <br /> TABLE 1 <br /> MARLEY COOLING TOWER <br /> STOCKTON, CALIFORNIA <br /> Lysimeter Sampling <br /> (October 17, 1990) <br /> Residual Vacuum <br /> Vacuum Reset <br /> Station centibars Time centibars Sample ID Notes <br /> L-5A 12 11:30 50- No Recovery. <br /> L-5B 0 11:40 -- No Recovery, <br /> Neoprene <br /> tubing <br /> damaged, <br /> Repair <br /> Needed. <br /> L-5C 0 11:40 No Recovery, <br /> Neoprene <br /> tubing <br /> damaged, <br /> Repair <br /> Needed. <br /> L-246 0 11:50 50 62751 Recovered <br /> 400 ml, <br /> clear yellow <br /> liquid. <br /> L-247 4 12:00 50 62752 Recovered <br /> 400 ml, <br /> clear yellow <br /> liquid. <br /> L-248 22 12:10 50 62753 Recovered <br /> 300 nil, <br /> clear brown- <br /> yellow liquid. <br /> L-242 22 12:40 50 62754 Recovered <br /> 250 ml, <br /> clear brown- <br /> yellow liquid. <br /> L-243 18 12:55 50 62755 Recovered <br /> 400 ml, <br /> clear brown- <br /> yellow liquid. <br /> L-244 24 13:10 50 62756 Recovered <br /> 100 ml, <br /> clear light- <br /> yellow liquid. <br /> F15-90-95 <br /> Copyright 1990 Kleinfelder, Inc. <br />