My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
FIELD DOCUMENTS_2000-2003
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WAGNER
>
200
>
2900 - Site Mitigation Program
>
PR0009002
>
FIELD DOCUMENTS_2000-2003
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/17/2020 3:11:07 PM
Creation date
6/17/2020 1:43:21 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
FIELD DOCUMENTS
FileName_PostFix
2000-2003
RECORD_ID
PR0009002
PE
2960
FACILITY_ID
FA0004040
FACILITY_NAME
SPX COOLING TECHNOLOGIES INC
STREET_NUMBER
200
Direction
N
STREET_NAME
WAGNER
STREET_TYPE
AVE
City
STOCKTON
Zip
95215
APN
14331007
CURRENT_STATUS
02
SITE_LOCATION
200 N WAGNER AVE
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
LSauers
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
397
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
WASTE DISCHARGE REQUALNTS ORDER NO.R5-2002-XXXX 8 <br /> MARLEY COOLING TOWER COMPANY <br /> SAN JOAQUIN COUNTY <br /> no credit provided for dilution. Since a site-specific translator has not been developed for copper <br /> as described in the SIP Section 1.4.1, the USEPA conversion factor was used in expressing the <br /> dissolved copper criterion as total recoverable. Acute and chronic effluent concentration <br /> allowance's (ECA's)were set equal to the adjusted acute and chronic copper criterion, and the <br /> most limiting long-term average (LTA) discharge condition for copper was determined from <br /> Table I of the SIP, using a coefficient of variation of 0.6. The average monthly effluent <br /> limitation(AMEL) and maximum daily effluent limitation (MDEL)were then calculated using <br /> multipliers in Table 2 of the SIP. <br /> New final average monthly(3.3 µg/l, (ppb) @ 44 mg/L(ppm)hardness as CaCO3) and daily <br /> maximum (6.5 µg/L(ppb) @ 44 mg/L(ppm)hardness as CaCO3) effluent limitations for copper <br /> (total)have been established in this Order in accordance with Sections 1.3 and 1.4 of the SIP <br /> using the adjusted copper criteria. These limitations will be adjusted accordingly with results of <br /> corresponding receiving water monitoring for hardness. The Discharger operates treatment <br /> processes specific to the removal of copper. With proper operation of the existing treatment <br /> facilities, results of monitoring indicate the Discharger is capable of meeting the new daily <br /> maximum effluent limitation, therefore a time schedule for compliance with this limitation is not <br /> included in this new Order. However,results of monitoring are not sufficient to determine if the <br /> Discharger can meet the new monthly average effluent limitation for copper of 3.3 µg/L (ppb) @ <br /> 44 mg/L(ppm) hardness as CaCO3. Data submitted by the Discharger indicates that, when the <br /> facility is properly operated, final effluent concentrations of copper are reported to be less than <br /> the detection limit of 5 µg/L(ppb). Historical data are not of sufficient quality to determine <br /> compliance with the new monthly average limitation. Detection of copper to 0.5 µg/L(ppb) is <br /> feasible in accordance with the SIP. This Order includes a Provision which requires the <br /> Discharger to collect data sufficient to determine compliance with this new monthly average <br /> effluent limitation for copper. <br /> As provided in Section 2.1 of the SIP, a time schedule is included in this Order to allow the <br /> Discharger to achieve compliance with the new monthly average effluent limitation for copper. <br /> In accordance with the SIP, Sections 2.2, a numeric monthly average interim limitation for <br /> copper is established in this Order based upon current treatment facility performance. Since the <br /> treatment facilities can, when properly operated, produce and effluent with copper concentrations <br /> less than 5 µg/L(ppb), this Order includes a performance based interim average monthly effluent <br /> limitation for copper set at this historical limit of detection of 5 gg/L(ppb). This interim <br /> limitation shall be an enforceable limitation until the final monthly average effluent limitation <br /> becomes effective on 1 October 2007. <br /> 20. Previous Order No. 93-221 included daily maximum and monthly average effluent limitations <br /> for hexavalent chromium based upon water quality objectives established by the California <br /> Inland Surface Waters Plan. Order No. 93-221 included a daily maximum limitation for <br /> hexavalent chromium of 11 µg/L(ppb), and a monthly average limitation for hexavalent <br /> chromium of 11 µg/L (ppb). New limits for hexavalent chromium have been established in this <br /> new Order based upon the reasonable potential to exceed the chronic freshwater aquatic life <br /> criterion in the CTR(new information). Results of final effluent monitoring indicate maximum <br /> effluent concentrations (MEC's) of hexavalent chromium have been high as 17 µg/L(ppb) <br />
The URL can be used to link to this page
Your browser does not support the video tag.