My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_WELL COMPLETION REPORT MW 4495D AND MW 4505D 20130301
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WAGNER
>
200
>
2900 - Site Mitigation Program
>
PR0009002
>
ARCHIVED REPORTS_WELL COMPLETION REPORT MW 4495D AND MW 4505D 20130301
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/17/2020 3:20:17 PM
Creation date
6/17/2020 1:56:27 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
ARCHIVED REPORTS
FileName_PostFix
WELL COMPLETION REPORT MW 4495D AND MW 4505D 20130301
RECORD_ID
PR0009002
PE
2960
FACILITY_ID
FA0004040
FACILITY_NAME
SPX COOLING TECHNOLOGIES INC
STREET_NUMBER
200
Direction
N
STREET_NAME
WAGNER
STREET_TYPE
AVE
City
STOCKTON
Zip
95215
APN
14331007
CURRENT_STATUS
02
SITE_LOCATION
200 N WAGNER AVE
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
LSauers
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
79
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 On July 10,2012 the depth-to-water was measured at 51.77 ft TOC at 7:15. It was <br /> difficult to detect the bottom of the well, so no measurement was recorded. The <br /> ' bailer was lowered 5 times to remove 15 gallons of water. The first bailer had some <br /> drilling mud and silty water,but subsequent bailers had no mud. <br /> The submersible pump was lowered to approximately 10 feet below the water level <br /> (approximately 80 feet above the top of the well screen). 478.6 gallons were pumped <br /> from the well in 24 minutes at an average rate of approximately 18 gallons per minute <br /> ' (GPM). Turbidity declined from a peak of 700 NTU to 350 NTU(Figure 10). <br /> Pumping was stopped and the submersible pump lowered to a few inches from the <br /> bottom of the well. Pumping resumed with the submersible pump raised gradually <br /> ' over the 15 feet of well screen. An additional 866.4 gallons were pumped from the <br /> well with the final turbidity measurement at 45 NTU. <br /> ' The bottom of well MW-4505 was measured at 160.01 ft TOC at the conclusion of <br /> development. <br /> ' 8.3 Well MW-449D <br /> Well MW-449D was developed on July 10, 2012. The initial depth-to-water was <br /> t measured at 56.00 feet below the top of casing(ft TOC) on July 10, 2012. The <br /> bottom of the well was measured at 169.1 ft TOC before development. <br /> t Initially, the bailer was lowered 15 times to remove approximately 45 gallons of <br /> water. The first bailer contained mostly drilling mud that settled at the bottom of the <br /> well. The next four bailers contained a mixture of drilling mud and water(described <br /> ' as a heavy, viscous fluid)with sand and silt. After the 15`h bailer, the well was surged <br /> for 20 minutes. The bailer was then lowered 10 additional times with the first couple <br /> bailers containing some fine sand and silt. Approximately 75 gallons were removed <br /> ' by the bailer. <br /> The submersible pump was lowered to approximately 14 feet below the water level <br /> ' (approximately 95 feet above the top of the well screen). 570 gallons were pumped <br /> from the well in 30 minutes at an average rate of approximately 19 gallons per minute <br /> (GPM). Turbidity declined from a peak of 2995 NTU to 35 NTU (Figure 11). <br /> ' Pumping was stopped and the submersible pump lowered to a few inches from the <br /> bottom of the well. Pumping resumed with the submersible pump raised gradually <br /> over the 15 feet of well screen set at this well. An additional 730 gallons were <br /> ' pumped from the well with the final turbidity measurement at 1.4 NTU. <br /> The bottom of well MW-449D was measured at 180.05 ft TOC at the conclusion of <br /> ' development. <br /> 8.4 Well MW-4495 <br /> ' Well MW-449S was developed on July 10, 2012. The initial depth-to-water was <br /> measured at 51.33 feet below the top of casing(ft TOC)on July 10, 2012. The <br /> bottom of the well was measured at 159.25 ft TOC before development. <br /> Well Completion Report for Monitor Well Pairs MW-449 and MW-450 7128-9 <br /> SPX Cooling Technologies Dudek <br /> ' Stockton,California Page 8 January 2013 <br />