Laserfiche WebLink
01 <br />UNDERGROUND STORAGE TANK <br />OVERFILL PREVENTION EQUIPMENT INSPECTION REPORT FORM (Page 1 of 1) <br />Type of Action MI Installation Inspection • Repair Inspection 1=136 Month Inspection <br />I. FACILITY INFORMATION <br />CERS ID Date of Overfill Prevention Equipment Inspection <br />11/8/2018 <br />Business Name (Same as Facility Name or DBA-Doing Business As) <br />Unified Grocers, Inc. <br />Business Site Address <br />1990 Piccoli Rd. <br />City <br />Stockton <br />ZIP Code <br />95215 <br />II. UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION <br />Name of UST Service Technician Performing the Inspection (Print as shown on the ICC Certification.) <br />Jarrett Flewellyn <br />Phone # <br />(714) 560-8222 <br />Contractor / Tank Tester License # <br />588098 <br />ICC Certification # <br />8028164 <br />ICC Certification Expiration Date <br />03-29-2019 <br />Overfill Prevention Equipment Inspection Training and Certifications (List applicable certifications.) <br />OPW -0174949 <br />III. OVERFILL PREVENTION EQUIPMENT INSPECTION INFORMATION <br />Inspection Method <br />Used: <br />CI Manufacturer Guidelines (Specify): Tape Measure <br />Industry Code or Engineering Standard (Specify): <br />0 Engineered Method (Specify): <br />Attach the inspection procedures and all documentation required to determine the results. # of Attached Pages <br />TANK ID: (By tank number, stored product, etc.) Diesel <br />What is the tank inside diameter? (Inches) 114 <br />Is the fill piping secondarily contained? 0 Yes E No MI Yes • No II Yes 0 No III Yes 0 No <br />Is the vent piping secondarily contained? I=1 Yes CI No U Yes • No Yes M No III Yes 0 No <br />Overfill Prevention Equipment Manufacturer(s) OPW 7130 <br />What is the overfill prevention equipment response <br />when activated? <br />(Check all that apply.) <br />El Shuts Off Flow <br />0 Restri cts Flow <br />AN Alarm <br />0 Shuts Off Flow <br />D Restricts Flow <br />0 AN Alarm <br />I=1 Shuts Off Flow <br />Restricts Flow <br />El A/V Alarm <br />Shuts Off Flow <br />0 Restricts Flow <br />D AN Alarm <br />Are flow restrictors installed on vent piping? 1:1Yes CI No 0 Yes II No M Yes MI No 0 Yes • No <br />At what level in the tank is the overfill prevention set <br />to activate? (Inches from bottom of tank.) 98" <br />What is the percent capacity of the tank at which the <br />overfill prevention equipment activates? 930/o <br />Is the overfill prevention in proper operating condition <br />to respond when the substance reaches the <br />ap . ropriate level? <br />IMI Yes <br />0 No (Specify in V.) <br />0 Yes <br />D No (Specify in V.) <br />0 Yes <br />0 No (Specify in V.) <br />0 Yes <br />0 No (Specify in V.) <br />IV. SUMMARY OF INSPECTION RESULTS <br />Overfill Prevention Inspection Results CI Pass M Fail 0 Pass • Fail I 0 Pass III Fail 0 Pass 0 Fail <br />V. COMMENTS <br />Any items marked "Fail" must be explained in this section. Any additional comments may also be provided here. <br />VI. CERTIFICATION BY UST SERVICE TECHNICIAN CONDUCTING THIS INSPECTION <br />I hereby certify that the overfill prevention equipment was inspected in accordance with California Code of Regulations, Title 23, <br />Division 3, Chapter 16, Section 2637.2 and all the information contained herein is accurate. <br />UST Service Technician Signature <br />Amok 9eeeveeeeps <br />the facility has more components than this form accommodates, additional copies of this page may be attached. <br />CERS = California Environmental Reporting System, ID = Identification, UST= Underground Storage Tank, ICC = International Code Council, AN= Audible and Visual