COMPLIANCE INFO_2020
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1001
>
2300 - Underground Storage Tank Program
>
PR0231876
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/10/2020 3:38:07 PM
Creation date
6/18/2020 10:58:28 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0231876
PE
2361
FACILITY_ID
FA0000421
FACILITY_NAME
DINO MART
STREET_NUMBER
1001
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
CURRENT_STATUS
01
SITE_LOCATION
1001 E YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\gmartinez
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
45
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN Environmental Healthrt <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name : Facility Address: Date : <br /> DINO MART 1001 E YOSEMITE AVE , MANTECA January 13 , 2020 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS 1, CLASS 11, or MINOR = Notice to Comply) <br /> Item # Remarks <br /> 209 CCR 2716 (a-e ) Failure to conduct the designated UST operator visual inspection at least once every 30 days . <br /> OBSERVATION: The designated operator failed to check and note all required items on the visual inspection <br /> reports . The incorrect and missing information included the following from the inspection reports : <br /> - THe DO reports of 8/25/19 and 4/ 10/19 , The owner operator failed to provide a name , signature and date within <br /> 48hos of receiving the DO report under the acknowledgment of compliance issues C A/6t.04v'0`0 <br /> -The DO reports of 12/ 18/ 19 , 3/13/ 19 and 2/ 13/ 19 did not include the name of owner/operator . CAR044C71r4� <br /> - The DO reports of 12/ 18/19 , 11 /20/ 19, 10/23/ 19 , 8/25/ 19 , 9/25/19 , 7/29/ 19 , 6/5/ 19 , 5/8/10 4/ 10/ 19 , 3/ 13/ 19 and <br /> 2/ 13/19 failed to add a description to all components marked /A or N from section VII through XI i9 �- >> - o • i°p3 <br /> XI tiSTF03 V.V. IN Z./Ab 2 S1CGTi' CVv 111 #9 blfcir .V07110 " Fol .144.. " 17,rms *V <br /> IN �cT/ON V • TM�'j /.V�UACti'tHT/an/ u/�►1S At/17�u94C.,��?li2 � O(lOL �.v/,E�c/ /4T 77�,�' T» .� <br /> p X ,10VOP� / A4S,40�C Tj p��1 <br /> REGU[ATION GUIDANCE: During the visual inspection , the designated operator shall check that all required <br /> testing and maintenance for the UST system have been completed and shall check all required items on the report. <br /> CORRECTIVE ACTION: Ensure that designated operators performing visual inspections at this facility are including <br /> all of the required information on the reports . <br /> This is a minor violation. <br /> 315 HSC 25291 (e ) Water in secondary containment not removed , analyzed , and properly disposed of (pre-Jul 2003) . <br /> OBSERVATION: Liquid was observed in the Diesel STP Sump , and UDC 7/8 SUMP . <br /> REGULATION GUIDANCE : If water could enter into the secondary containment by precipitation or infiltration , it <br /> must be removed and disposed of properly . <br /> CORRECTIVE ACTION: The service technician removed approximately halve a gallon of liquid from the diesel <br /> STP sump and UDC 7/8 sump . Ensure that all sumps and annular spaces are maintained free of liquid . <br /> This is a minor violation. C&.R 7 F�7 <br /> 320 CCR 2635 , 2637 . 2 , 2665 , 2712 Failure to comply with the installation , inspection , or record keeping of the overfill <br /> prevention . <br /> OBSERVATION: The diesel mechanical flappers used as the overfill prevention system were marked as failures on <br /> the 10/ 11 / 18 Overfill Prevention Equipment Inspection Report. <br /> REGULATION GUIDANCE : All UST systems must be equipped with an approved , functional overfill prevention <br /> device at all times during delivery operations . <br /> CORRECTIVE ACTION: Immediately discontinue deposition of petroleum into this tank until the component is <br /> repaired or replaced by a properly licensed , trained , and certified contractor under permit and inspection of the EHD . <br /> If the failed component can 't be replaced immediately, there is a possibility that the diesel UST system may be red <br /> tagged to prevent fuel inputs . <br /> This is a Class II violation . LocJOR/C /nJG O/V ;el (IN! <br /> Overall Inspection Comments . <br /> FA0000421 PR0231876 SCO01 01 /13/2020 <br /> EHD 23-01 Rev. 9/20/2019 Page 6 of 7 Underground Storage Tank Program OIR <br /> 1868 E . Hazelton Avenue ( Stockton , California 95205 1 T 209 468-3420 F 209 464-0138 1 www . sjcehd . com <br />
The URL can be used to link to this page
Your browser does not support the video tag.