My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS_XR0008137
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WEST
>
2801
>
2900 - Site Mitigation Program
>
PR0504943
>
ARCHIVED REPORTS_XR0008137
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/18/2020 1:13:26 PM
Creation date
6/18/2020 12:09:44 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0008137
RECORD_ID
PR0504943
PE
2951
FACILITY_ID
FA0004032
FACILITY_NAME
AMERICAN MOULDING & MILLWORK (FRMR)
STREET_NUMBER
2801
STREET_NAME
WEST
STREET_TYPE
LN
City
STOCKTON
Zip
95204
APN
11709001
CURRENT_STATUS
02
SITE_LOCATION
2801 WEST LN
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
LSauers
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
150
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DATA VALIDATION REASON CODE DESCRIPTIONS <br /> The following descriptions provide brief explanations of the cause for <br /> qualification of the data results determined in the data review process These reason <br /> codes are used in combination with the data qualifier, i e "U" indicates the analyte <br /> i <br /> is non-detect due to method blank contamination <br /> Flag Data Qualifier Exolanation <br /> a Analytical sequence deficiency or omission <br /> b Gross compound breakdown (4,4 DDT/Endrin) <br /> c Calibration failure, poor or unstable response <br /> d Matrix spike/matrix spike duplicate imprecision or matrix duplicate imprecision <br />' e Laboratory duplicate control sample imprecision <br /> f Field replicate or duplicate imprecision <br /> g Poor chromatography <br /> h Holding time violation. <br /> I Internal standard failure. <br /> I Poor mass spectrographic performance <br /> 1 Laboratory control sample recovery failure <br /> em Matrix spike/matrix spike duplicate recovery failure. <br /> n Interference check sample recovery failure <br /> o Calibration blank contamination (Metals/Inorganics only). <br /> p Preparation blank contamination (Metals/l norganics only) <br /> q No valid quantitation column present <br /> r Linearity failure in initial calibration <br /> s Surrogate spike recovery failure (GC Organics and GC/MS Organics only) <br /> t Instrument tuning failure. <br /> u No confirmation column present (GC Organics only) <br /> w Retention time (RT) outside of RT window <br /> x Field blank contamination <br /> y Trip blank contamination. <br /> z Method blank contamination <br /> Q Other. <br /> TIMS01 01 <br />
The URL can be used to link to this page
Your browser does not support the video tag.