Laserfiche WebLink
UNDERGROUNDSTORAGETANK <br /> SECONDARY CONTAINMENT TESTING REPORT FORM (Pagel of 6) <br /> Type of Action ❑Installation Test ❑Repair Test ❑Six Month Test ❑x 36 Month Test <br /> I. FACILITY INFORMATION <br /> CERS ID Date of Secondary Containment Test <br /> 10181611 9/15/2020 <br /> Business Name(Same as Facility Name or DBA-Doing Business As) <br /> Jahant Food N Fuel Stop <br /> Business Site Address City ZIP Code <br /> 24323 North Highway 99 Acam o 95220 <br /> II. UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION <br /> Name of UST Service Technician Performing the Test(Print as shown on the ICC Certification) Phone# <br /> Benjamin Duncan (707) 621-0378 <br /> Contractor/Tank Tester License# ICC Certification# ICC Certification Expiration Date <br /> Tank Tester License #90-1120 5246802-UT 3/21/2021 <br /> III. SUMMARY OF SECONDARY CONTAINMENT TESTING RESULTS <br /> TANK ID: (Bytanknumber,storedproduct,etc.) A T-1-Diesel B T-2-Regular 87 C T-3-Plus 89 D T-4-Super 91 <br /> Tank Containment <br /> Tightness Test Result O Pass El Fail ElNA O Pass ❑Fail ❑ NA O Pass El Fail ElNA O Pass ❑ Fail ElNA <br /> Product Piping Containment <br /> Tightness Test Result E Pass ❑Fail ❑NA E Pass ❑Fail ❑ NA O Pass ❑Fail ❑ NA E Pass ❑Fail ❑NA <br /> Communication Test Result E Pass ❑ Fail ❑NA E Pass ❑Fail ❑NA E Pass ❑Fail ❑ NA E Pass ❑Fail ❑ NA <br /> Remote Fill Piping Containment <br /> Tightness Test Result ❑Pass ❑ Fail E NA ❑ Pass ❑Fail E NA ❑Pass ❑ Fail E NA ❑ Pass ❑Fail E NA <br /> Communication Test Result ❑Pass ❑Fail E NA ❑ Pass EE] ail E NA ❑Pass ❑Fail E NA ❑Pass ❑Fail E NA <br /> Vent Piping Containment <br /> Tightness Test Result ❑Pass ❑Fail E NA ❑Pass ❑ Fail E NA ❑Pass ❑ Fail E NA ❑Pass ❑ Fail E NA <br /> Communication Test Result ❑Pass ❑Fail E NA ❑Pass ❑Fail E NA ❑Pass ❑ Fail E NA ❑Pass ❑Fail E NA <br /> Vapor Recovery Piping Containment <br /> Tightness Test Result ❑Pass ❑Fail E NA ❑Pass ❑Fail E NA ❑Pass ❑Fail E NA ❑Pass ❑Fail E NA <br /> Communication Test Result ❑Pass ❑Fail E NA ❑Pass ❑Fail O NA ❑Pass ❑ Fail E NA ❑Pass [I Fail I!]NA <br /> Turbine/Product Piping Sump <br /> Tightness Test Result E Pass ❑ Fail ❑NA E Pass ❑Fail ❑ NA E Pass ❑ Fail ❑NA E Pass ❑ Fail ❑ NA <br /> Fill Riser Sump <br /> Tightness Test Result ❑Pass ❑ Fail E NA ❑Pass ❑Fail E NA ❑ Pass ❑ Fail E NA ❑Pass ❑ Fail E NA <br /> VENT/TRANSITION SUMP ID: a b c d <br /> Tightness Test Result ❑Pass ❑Fail E NA ❑Pass ❑Fail E NA [I Pass ❑Fail E NA ❑Pass ❑ Fail E NA <br /> UDC ID: 1 1&2 2 3&4 3 5&6 4 7&8 <br /> Tightness Test Result E Pass ❑Fail ❑NA E Pass ❑Fail ❑NA E Pass ❑Fail ❑NA IF]Pass ❑Fail ❑NA <br /> UDC ID: 5 9&10 6 11&12 7 13&14 8 15&16 <br /> Tightness Test Result E Pass ❑Fail ❑NA E Pass ❑Fail ❑NA E Pass ❑Fail ❑NA E Pass ❑Fail ❑NA <br /> UDC ID: 9 10 11 12 <br /> Tightness Test Result ❑Pass ❑Fail ❑NA ❑Pass ❑Fail ❑NA El Pass [:1 Fail ❑NA E]Pass ❑Fail ❑NA <br /> All items marked"Fail"or"NA"must be explained in their respective"COMMENTS"section. <br /> IV. CERTIFICATION BY UST SERVICE TECHNICIAN CONDUCTING THIS TESTING <br /> I hereby certify that the secondary containment was tested in accordance with California Code of Regulations,Title 23,Division <br /> 3,Chapter 16,Section 2637 and all the information contained herein is accurate. ,., <br /> UST Service Technician Signature � <br /> —i����ti17m2G11i ��G�inCQ�li� <br /> CERS=California Environmental Reporting System,ID=Identification,UST=Underground Storage Tank,ICC=International Code Council,NA=Not Applicable,UDC=Under- <br /> Dispenser Containment ENVIRONMENTAL HEALTH <br /> PERMIT/SERVICES <br />