My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
V
>
VICTOR
>
1400
>
2300 - Underground Storage Tank Program
>
PR0231951
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/5/2021 8:53:22 AM
Creation date
6/18/2020 2:42:47 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0231951
PE
2361
FACILITY_ID
FA0003704
FACILITY_NAME
DART CONTAINER CORP
STREET_NUMBER
1400
Direction
E
STREET_NAME
VICTOR
STREET_TYPE
RD
City
LODI
Zip
95240
APN
04932015
CURRENT_STATUS
01
SITE_LOCATION
1400 E VICTOR RD
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
56
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNDERGROUND STORAGE TANK <br /> DESIGNATED UNDERGROUND STORAGE TANK OPERATOR VISUAL INSPECTION REPORT (Page 2 of 2) <br /> Vii . INSPECTION HISTORY <br /> Has each follow-up action of Section III from the previous inspection been completed appropriately? Y N _- <br /> Attach documentation verifying appropriate service to this report. ❑ <br /> VIII . ALARM HISTORY <br /> Attach a copy of the alarm hlstoryreportllog to this report. Y I N INA <br /> Is the monitoring system powered on and in proper operating mode? D 1 ❑ ❑ <br /> Has each leak detection alarm since the previous inspection been responded to appropriately? ❑ w 04C. <br /> Attach documentation vedWng appropriate service to this report. JAI 1 <br /> Have all containment sumps that have had a leak detection alarm since the previous inspection been responded to by a ❑ � � <br /> qualified UST Service Technician? <br /> List below in Section 1X all containment sumps that have had a leak detection alarm since the previous Inspection and have not been <br /> responded to by a qualified UST Service Technician. Containment sumps listed below require a visual inspection for damage, water, debris, <br /> hazardous substance, and propersensorlocation, The results of the visual inspection must be recorded In Section IX. <br /> IX. UNDERGROUND STORAGE TANK SYSTEM INSPECTION <br /> Is the containment sump free of damage, water, debris , and hazardous substance? <br /> Containment Sump ID Y N Containment Sump ID Y N <br /> Dsl 0 ❑ ElEl <br /> ❑ ❑ ❑ ❑ <br /> ❑ ❑ ❑ ❑ <br /> ❑ ❑ ❑ ❑ <br /> Are all sensors in containment sumps Inspected located to detect a leak at the earliest opportunity? ❑ <br /> Is the spill container free of damage, water, debris, and hazardous substance? <br /> Tank ID Dsl 0 ❑ Tank ID , ❑ PEr-1 ❑ TankID El <br /> Is the fill pipe free of obstructions? <br /> Tank ID Dsl 91 ❑ I Tank ID ❑ ❑ <br /> TanklD ❑ ❑ Tank ID ❑ LEI <br /> Is the fill cap securely on the fill pipe ? <br /> Tank ID Dsl C7 ❑ Tank ID ❑ ❑ <br /> Tank ID ❑ ❑ Tank ID ❑ I ❑ <br /> Is the under-dispenser containment free of damage, water, debris, and hazardous substance? <br /> Under- Dispenser Containment ID Y I N INA Under-Dispenser Containment ID Y N NA <br /> i <br /> Dispenser 1 /2 01 ❑ 0 Dispenser 3/4 ❑ ❑ ❑ <br /> Dispenser 5/6 ❑ ❑ IR Dispenser 7/8 ❑ ❑ ❑ <br /> Dispenser 9/10 ❑ ❑ CI Dispenser 11 /12 ❑ ❑ ❑ <br /> ❑ ❑ . 111:10 171❑ ❑ ❑ & ic? fie. k _ r.5 ❑ ❑ ❑ <br /> ❑ <br /> EI I ,� , � ; � I - r , , fool A ❑ ❑ 1 ❑ <br /> Are all sensors in under-dispenser containment located to detect a leak at the earliest opportunity? ' ► F MEl ❑ <br /> X. TESTING AND MAINTENANCE Y N NA Date Last <br /> Performed <br /> Has the monitoring system certification been completed within the past 12 months? ❑ {1 r �{ <br /> Has the spill container testing been completed within the past 12 months? ❑ ' } - ) <br /> Has the overfill prevention equipment inspection been completed within the past 36 months? ❑ ❑ 81111. poo D <br /> Has the secondary containment testing been completed within the past 36 months? 0 ❑ ❑ <br /> Has the tank tightness testing been completed within required timeframes? ❑ ❑ . <br /> Has the line tightness testing been completed within the required timeframes? ❑ ❑ �7 <br /> Other required testing / maintenance was completed within required timeframe. (List test/maintenance items below.) <br /> Test / Maintenance: DO Traininq N I ❑ <br /> Test / Maintenance: ❑ ❑ <br /> Test / Maintenance: ❑ ❑ <br /> Test / Maintenance : ❑ ❑ <br /> Test / Maintenance : ❑ ❑ <br /> Test / Maintenance: ❑ ❑ <br /> Xi . FACILITY EMPLOYEE TRAINING Y N <br /> Have all individuals performing facility employee duties received the required facility employee training within the past 12 months? 191 ❑ <br /> I the facilitylras more components than this form accommodates, additional copies of this page maybe attached. <br /> Y = Yes, N = No, NA = Not Appllcable, ID = ldenHcafion <br />
The URL can be used to link to this page
Your browser does not support the video tag.