Chevron Monitoring Certification Checklist <br /> Store Number: 94275 Address: 2905 W. BENJAMIN HOLT @ I-5 STOCKTON, CA 95207 <br /> Date : 2/20/2020 Technician : Jesus Saldivar [Company: TANKNOLOGY INC. <br /> Step Instruction T2 T1 T3 <br /> Product REG UNLEAD SUPREME DIESEL2 <br /> Tank Type Fiberglass Fiberglass Fiberglass <br /> (DW FRP, DW Steel, SW FRP) <br /> 1 Annular Riser Height ( measured ) <br /> 2 Tank Diameter: (from tank chart, 118 .75 in. 118 . 75 in. 118 .75 in , <br /> for example: 118. 375 ", 117. 75 , 111 ",92 ", etc.) <br /> 3 For FRP tanks, 1/2 circumference of the tank 186 .44 in. 186 .44 in. 186 .44 in. <br /> (0.3 X 3. 14 X tank diam.) OR (q.57 x step 2) <br /> Required annular sensor length : <br /> 186 .44 in. 186 .44 in. 186 .44 in. <br /> 4 FRP = Riser + 112 circumference = stepI + step3 <br /> Steel = Riser + diameter = step 1 + step 2 <br /> Mark & label the required sensor length on <br /> 5 sensor cord . Label should be under the cap & Yes Yes Yes <br /> serve to prevent the cord being pulled too short. <br /> is tank annular sensor in the correct position ? <br /> Yes Yes Yes <br /> 6 FRP Tanks: with the marked required length <br /> lining up with the top of the annular riser? Yes Yes Yes <br /> Steel Tanks: sensor touching bottom with slack <br /> above the marked required sensor length ? <br /> Are the DW pipe boots pulled back in tank sumps? <br /> 8 (YIN or N/A, note if can 't be verified because Yes Yes Yes <br /> clamshell pointing down) <br /> Are tank sump sensors back in their holders and <br /> 9 in the correct position ? Yes Yes Yes <br /> (YIN or N/A document with photo) <br /> 7 Approximate gallons of product dispensed for <br /> purging, etc . and returned to tank <br /> Has the Veeder Root Battery been replaced & dated prior to failsafe? Replaced in Last 30 Days <br /> (If battery backup failed, label and leave failed battery on top of console, note in comments and advise your OM) <br /> Has Veeder Root Programming before & after testing been printed & verified ? Yes <br /> (especially tank manifolding setup - see Note 2) <br /> Has Veeder Root Programming before & after been attached to the Work Order? Yes <br /> Have all sensor model numbers been verified against the Veeder Root cord label ? Yes <br /> Make a note if sensor label missing or illegible, & approx. cord length for -208/-209 with missing labels <br /> Additional Comments: <br /> ALLTANK ANNULARS ARE 303 BRINE SENSORS. . . <br /> Note 1: Certain Veeder Root Software versions will automatically revert to the default tank manifold settings anytime the programming is changed, such as when sensors are <br /> temporarily Ved out, etc. <br />