Laserfiche WebLink
Alpha Analytical, Inc. <br /> 255 Glendale Ave. •Suite 21 •Sparks,Nevada 89431-5778 <br /> (775)355-1044•(775)355-0406 FAX• 1-800-283-1183 <br /> Date: <br /> 24-MWork Order: <br /> 24-Mar-la QC Summary Report Work <br /> 0702 <br /> Ode <br /> Method Blank Type MBLK Test Code: EPA Method SW8015B/C/SW8260B <br /> File ID. C:IHPCHEMIMSI0\DATA\140310\14031004.D Batch ID: MSIOW0310B Analysis Date: 03/10/2014 10:32 <br /> Sample ID: MBLK MSIOW0310B Units: mg/L Run ID:MSD_10_140310A Prep Date: 03110/2014 10:32 <br /> Analyte Result PQL SpkVal SpkRefVal %REC LCL(ME) UCL(ME)RPDRefVal %RPD(Limit) Qual <br /> TPH-P(GRO) ND 0.5 <br /> Surr: 1,2-Dichloroethane-d4 0.00964 0.01 96 70 130 <br /> Surr:Toluene-d8 0.00998 0.01 99.8 70 130 <br /> Surr:4-Bromofluorobenzene 0.00952 0.01 95 70 130 <br /> Laboratory Control Spike Type LCS Test Code: EPA Method SW8015B1C/SW8260B <br /> File ID: C:IHPCHEM\MSIOIDATA\140310114031003.D Batch ID:MS10W0310B Analysis Date: 03/10/201410:01 <br /> Sample ID: GLCS MSIOW0310B Units: mg/L Run ID:MSD_10_140310A Prep Date: 03/10/2014 10:01 <br /> Analyte Result PQL SpkVal SpkRefVal %REC LCL(ME) UCL(ME)RPDRefVal %RPD(Limit) Qual <br /> TPH-P(GRO) 0.417 0.05 0.4 104 70 130 <br /> Surr: 1,2-Dichloroethane-d4 0.00994 0.01 99 70 130 <br /> Surr:Toluene-d8 0.00947 0.01 95 70 130 <br /> Surr:4-Bromofluorobenzene 0.00955 0.01 96 70 130 <br /> Sample Matrix Spike Type MS Test Code: EPA Method SW8015B/C/SW8260B <br /> File ID: C:IHPCHEM\MS10\DATA\140310\14031017.D Batch ID: MSIOW0310B Analysis Date: 03/10/2014 15:08 <br /> Sample ID: 14030702-01AGS Units:mg/L Run ID:MSD_10_140310A Prep Date: 03/10/201415:08 <br /> Analyte Result PQL SpkVal SpkRefVal %REC LCL(ME) UCL(ME) RPDRefVal %RPD(Limit) Qua[ <br /> TPH-P(GRO) 2.19 0.25 2 0 110 54 143 <br /> Surr: 1,2-Dichloroethane-d4 0.0497 0.05 99 70 130 <br /> Surr:Toluene-d8 0.047 0.05 94 70 130 <br /> Sum 4-Bromofluorobenzene 0.0469 0.05 94 70 130 <br /> Sample Matrix Spike Duplicate Type MSD Test Code: EPA Method SW8015B/C/SW8260B <br /> File ID:C:\HPCHEMIMS10\DATA\140310\14031018.D Batch ID:MS10W0310B Analysis Date: 03/10/201415:29 <br /> Sample ID: 14030702-01AGSD Units: mg/L Run ID:MSD 10 140310A Prep Date: 03/1012014 15:29 <br /> Analyte Result PQL SpkVal SpkRefVal %REC LCL(ME) UCL(ME)RPDRefVal %RPD(Limit) Qual <br /> TPH-P(GRO) 2.09 0.25 2 0 104 54 143 2.19 4.8(23) <br /> Surr: 1,2-Dichloroethane-d4 0.0495 0.05 99 70 130 <br /> Surr Toluene-d8 0.0472 0.05 94 70 130 <br /> Surr 4-Bromofluorobenzene 0.0474 0.05 95 70 130 <br /> Comments: <br /> Calculations arc based off of raw(non-rounded)data.However,for reporting purposes,all QC data is rounded to three significant figures.Therefore,hand calculated <br /> values may differ slightly. <br /> i <br /> i <br />