My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2019
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
S
>
SCHULTE
>
14800
>
2200 - Hazardous Waste Program
>
PR0514124
>
COMPLIANCE INFO_2019
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/23/2020 2:09:32 PM
Creation date
6/23/2020 10:22:22 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2200 - Hazardous Waste Program
File Section
COMPLIANCE INFO
FileName_PostFix
2019
RECORD_ID
PR0514124
PE
2220
FACILITY_ID
FA0004471
FACILITY_NAME
THERMAL ENERGY DEVELOP PSHIP
STREET_NUMBER
14800
Direction
W
STREET_NAME
SCHULTE
STREET_TYPE
RD
City
TRACY
Zip
95377
APN
20924023
CURRENT_STATUS
02
SITE_LOCATION
14800 W SCHULTE RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\dsedra
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
198
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN 10 A Q U I N A84EMD9 Environmental Health Department <br /> - COUNTY - <br /> Small <br /> COUNTY Small Quantity Hazardous Waste Generator Inspection Report <br /> Facility Name: Facility Address : Date : <br /> THERMAL ENERGY DEVELOP PSHIP 14800 W SCHULTE RD TRACY May 20 2019 <br /> Labeling and Storage <br /> 610 CCR 66262. 34 (b) (1 ) Stored acutely or extremely hazardous waste onsite greater than 90 days ❑ V o R ❑ COS <br /> 611 HSC 25200. 3 . 1 (b) Failure of laboratory to comply with hazardous waste accumulation area requirements ❑ V a R ❑ COS <br /> Universal Waste <br /> 701 CCR 66273 . 32 (a) UW handler failed to notify EPA RA and obtain an EPA ID # prior to accumulating >5000kg of UW ❑ V o R ❑ COS <br /> 702 CCR 66273. 32(c) Electronic device and CRT handler failed to notify DTSC 30 days prior to accepting offsite UW ❑ V a R ❑ COS <br /> 703 CCR 66273. 33(a) UW handler failed to store UW batteries in a manner that prevents release to the environment o V ❑ R o COS <br /> 704 CCR 66273 . 33(b) UW handler failed to properly manage universal waste lamps n V o R ❑ COS <br /> 705 CCR 66273. 33(c) UW handler failed to properly manage mercurycontaining universal waste ❑ V ❑ R o COS <br /> 706 CCR 66273. 33 .5 UW handler failed to prevent release of universal waste electronic devices, CRTs or CRT glass ❑ V o R o COS <br /> 707 HSC 25201 . 16(e) Failed to manage aerosol cans in a manner that prevents the unauthorized release of waste o V ❑ R a COS <br /> 708 HSC 25201 . 16(f) Failed to properly manage containers of waste aerosol cans ❑ V o R o COS <br /> 709 HSC 25201 . 16(g) Failed to store used aerosol cans in an accumulation container a V o R o COS <br /> 710 HSC 25201 . 16 (h) (4) No written operating procedure for aerosol can processing o V o R ❑ COS <br /> 711 HSC 25201 . 160) Failed to submit or amend notification for aerosol can processing ❑ V ❑ R o COS <br /> 712 CCR 66273. 34 UW handler (UWH) failed to label universal waste to identify type of universal waste o V ❑ R ❑ COS <br /> 713 CCR 66273 . 35 UWH stored UW onsite greater than one year or was unable to demonstrate storage time ❑ V o R a COS <br /> 714 CCR 66273. 36 UWH failed to train employees and maintain records on UW handling and emergency procedures o V ❑ R ❑ COS <br /> 715 CCR 66273. 39 UWH failed to keep complete records of each shipment of universal waste for three years o V ❑ R ❑ COS <br /> 716 CCR 66273.40(a) (3) (4) UW handler sending devices/CRTs/CRT glass to foreign destination failed to submit notification ❑ V o R o COS <br /> 717 CCR 66273. 32(b) UWH failed to obtain an ID number from DTSC prior to accumulating >5000kg of non-RCRA UW o V ❑ R ❑ COS <br /> 718 CCR 66273. 32 (d) Failure of a UW handler to submit a complete annual report to DTSC ❑ V o R ❑ COS <br /> 719 CCR 66273. 38 Failure of UW handler to transfer UW to the appropriate destination facility ❑ V a R o COS <br /> 720 CCR 66273, 31 (a) UW handler caused improper disposal of UW o V ❑ R ❑ COS <br /> 721 CCR 66273. 8(b) Conditionally exempt small quantity UW generator caused improper disposal of UW ❑ V o R o COS <br /> Appliance Recycler <br /> 801 HSC 25211 .4 Failure to obtain Certified Appliance Recycler certification (CAR) o V ❑ R n COS <br /> 802 HSC 25211 . 21 25211 .3 Failure of a CAR to provide docs that materials that require special handling have been removed ❑ V o R o COS <br /> 803 HSC 25212 Failure of a CAR to properly remove and dispose of all materials that require special handling ❑ V a R o COS <br /> Other Violations <br /> 3010 See below Unlisted Administration/Documentation violation o V ❑ R o COS <br /> 3020 See below Unlisted Training violation o V ❑ R o COS <br /> 3030 See below Unlisted Operations/Maintenance violation ❑ V o R ❑ COS <br /> 3040 See below Unlisted Release/Leaks/Spills violation o V ❑ R o COS <br /> 3050 See below Unlisted Abandonment/Illegal Disposal/Unauthorized Treatment violation ❑ V o R ❑ COS <br /> FA0004471 PR0514124 SCO01 05/20/2019 <br /> EHD 22-01 Rev. 09/27/2018 Page 3 of 7 Small Quantity Hazardous Waste Generator OIR <br /> 1868 E . Hazelton Avenue Stockton , California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www. sjcehd . com <br />
The URL can be used to link to this page
Your browser does not support the video tag.