Laserfiche WebLink
TAN 3 <br /> VAPOR REMEDIATION SYSTEM STATUS <br /> THRIFTY OIL STATION#171, STOCKTON, CA <br /> Hour meter Hours of Vapor Inlet TPHg TPHg removed Cumulative TPHg Mass Volume <br /> Date reading Operation Flow Rate Concentration within period TPHg removed Removal Rate Removed <br /> (hrs)- i (his) (cfm) (Ppmv) (ug1L) (lbs) (lbs) (lbs/hr) (gallons) Remarks <br /> 07/01199 13 312 0 100 12 000 - Start up system hour meter=13 312 <br /> 07112199 13 508 196 80 3 300 3 354 07 3 354 17 11 5324 <br /> 07/28199 13 566 58 144 7 900 904 16 4 258 1559 6759 <br /> 08124/99 13 705 139 100 6000 2 929 35 7 188 21 07 1 1409 <br /> 09/14/99 14 207 502 188 8 700 13 205 82 20 393 2631 3 237 0 <br /> 10114/99 14 927 720 189 2 800 19 396 50 39 790 2694 6 315 9 <br /> 11/09/99 15 537 610 188 1 000 5 430 08 45 220 890 7 177 8 <br /> 12/15/99 16 288 751 190 19 1 797 45 47 017 239 7 463 1 <br /> D1118100 17 042 754 183 790 1 41378 48 431 1 88 7 687 5 <br /> 02/01/00 17 307 265 95222 49 383 369 7 838 6 System off for Hower motor replacement <br /> 02/22/00 17 307 0 - 49 383 - 7 838 6 Restart <br /> 03/21/00 17 978 671 179 985 4 020 1 80581 51 189 269 8 1253 <br /> 04/18/00 18 621 643 176 642 2 620 1 417 16 52 606 220 8 350 2 <br /> 05/16/00 19 314 693 196 _ 47 192 67780 53 284 098 8 457 8 <br /> 05123/00 19 315 1 - 192 014 53 284 014 8 457 8 System off for repaalmamtenance <br /> 06120/00 19 315 0 192 - 53 284 8 457 8 System still off <br /> 07103/00 19 315 0 192 - 53 284 - 8 457 8 Restart <br /> 07/11100 19 504 189 180 27 119 19 79 53 304 0 10 8 461 0 <br /> 08109/00 19 775 271 181 10 42 1473 53 319 005 8 463 3 <br /> 09/20100 20 409 634 182 25 110 3271 53 352 005 $4665 <br /> 10/10100 20 886 477 182 110 3572 53 387 007 8 474 2 System down due to small blower problem <br /> 10/24/00 20 889 3 182 110 022 53 388 007 8 474 2 Fored small blower Attempted to restart VES blower problem shut system off <br /> 10/31/00 20 889 0 53 388 - 8 474 2 Removed VES blower for replacement Sent to L4 on 1112M <br /> 11/07/00 20 889 0 53 388 8 474 2 Installed replacement blower tried to startup but blower motor got burned <br /> 11/08100 20 889 0 53 388 8 474 2 Dismantled blower motor and return to Grainger for warranty repairrrepfiacement <br /> 11/28/00 20 889 0 53 388 8 474 2 System still off waiting for Grainger to finish the blower motor repair <br /> 12119100 20 889 0 - 53 388 8 474 2 System still off ror repair operator on vacation <br /> 01/09101 20 889 0 53 388 - 8 474 2 Installed replacement motor blower restarted system <br /> 01123/01 21 042 Y 153 219 1111 1378 53 401 0119 8 476 4 Found system off restarted after adjustment of oxygen controller <br /> 01/30/01 21 207 165 214 110 1470 53 416 009 8 478 7 <br /> 171ves Page 1 of 8/18/03 <br />