Laserfiche WebLink
0 , - <br /> TABLE 3 <br /> VAPOR REMEDIATION SYSTEM STATUS <br /> THRIFTY OIL STATION#171, STOCKTON, CA <br /> Hour meter Hours of Vapor Inlet TPHg TPHg removed Cumulattve TPHg Mass Volume <br /> Date reading Operation Flow Rate Concentration within penod TPHg removed Removal Rate Removed <br /> (hrs)" (hrs) Win) (ppmv) (ug1L) (lbs) (Ibs) (lbs/hr) (gallons) Remarks <br /> 07/01/99 13 312 0 100 12 000 Start up system hour meter=13 312 <br /> 07112!99 13 508 196 so 3 300 3 354 07 3 354 1711 5324 <br /> 07128199 13 566 58 144 7 900 904 16 4 258 1S59 6759 <br /> 08/24/99 13 705 139 100 6 000 2 929 35 7 188 21 07 1 1409 <br /> 09/14/99 14 207 502 188 $700 13 205 82 20 393 2631 3 237 0 <br /> 10/14/99 14 927 720 189 2 800 19 396 50 39 790 2694 6 315 9 <br /> 11/09/99 15 537 610 188 1 000 5 430 08 45 220 890 7 177 8 <br /> 12!15199 16 288 751 190 19 1 79745 47 017 239 7 463 1 <br /> 01/18100 17 042 754 183 790 1 41378 48 431 1 88 7 687 5 <br /> 02/01100 17 307 265 95222 I 49 383 359 7 838 6 System oft for blower motor replacement <br /> 02/22/00 17 307 0 ^ - 49 383 7 838 6 Restart <br /> 03/21/00 17 978 671 179 985 4 020 1 80581 51 189 2691 8 125 3 <br /> 04/18/00 18 621 643 1176 642 2 620 1 41718 52 606 220 8 350 2 <br /> 05/16/00 19 314 693 196 47 192 67780 53 284 098 8 457 8 <br /> 05/23/00 19 315 1 192 014 53 284 014 84578 System off for repairlmaintenance <br /> 06/20/00 19 315 0 192 53 284 - 8 457 8 system still off <br /> 07/03/00 19 315 0 192 53 284 84578 Restart <br /> 07/11100 19 504 189 180 27 119 1979 1 53 304 010 8 461 0 <br /> 08/09/00 19 775 271 181 10 42 1473 53 319 005 8 463 3 <br /> 09/20/00 20 409 634 182 25 110 3271 53 352 005 8 468 5 <br /> 10110100 20 886 477 1B2 110 3572 53 387 007 8 474 2 system down due to small blower problem <br /> 10/24/00 20 889 i 3 182 110 022 53 388 007 8 474 2 Fixed small blower Attempted to restart VES blower problem shut system oft <br /> 10/31100 20 889 0 53 388 8 474 2 Removed VES blower for replacement Sent to LA on 1112M <br /> 11/07/00 20 889 0 53 388 8 474 2 Installed replacement blower tried to startup but blower motor pot burned <br /> 11/08/00 20 889 0 53 388 8 474 2 Dismantled Mower motor and return to Graingerfor warranty repaufreplacement <br /> 11/28/00 20 869 j 0 53 388 8 474 2 System sblf off waiting for Grainger to finish the blower motor repair <br /> 12/19/00 20 889 0 53 388 8 474 2 System stall off for repair operator on varaton <br /> 01/09/01 20 889 0 53 388 8 474 2 Installed replacement motor blower restarted system <br /> 01/23/01 21 042 153 219 110 1378 I 53 401 009 8 476 4 Found system off restarted after adjustment of oxygen controller <br /> 61130101 25 2T 165 214 110 1470 53 416 009 1 8 478 7 <br /> 171ves Page 1 of 6 6111/03 <br />