_ 3 _ Qr-"C <br /> S <br /> V. <br /> L <br /> Coca-Cola Enterprises - West <br /> Job No. 90054 <br /> 3.0 ANALYTICAL PROCEDURES <br /> S011 gas samples were analyzed using gas chromatographic techniques which identify and <br /> measure concentrations of the v"rious compounds. Samples were injected directly into a <br /> gas chromatograph equipped with a flame ionization detector (FID) for analysis of total <br /> hydrocarbons. <br /> The make and model of the equipment used to perform these on-site analysis included: <br /> o Hewlett Packard 5890 Gas Chromatograph <br /> o Flame Ionization (FID) Detector <br /> o 15 feet by 0.53u RT-5 Y Bore Capillary <br /> 0 336 Computer with Hewlett Packard Chem Station software <br /> Quality assurance and quality control (QA/QC) were achieved through strict experimental <br /> Protocol- <br /> QA/QC procedures are included in the Optimal Technology report (Appendix A). <br /> Chain-of-custody procedures were obsern, <br /> ed for all samples collected. All parts of the <br /> collection system that came in contact with a sample were decontaminated before each use. <br /> Three calibration runs were performed at the beginning of each day and an additional <br /> l calibration run after every 10 samples. A system blank was analyzed at the beginning of <br /> each day and between each sample. About 50% of the soil gas samples were analyzed in <br /> duplicate. <br /> i : . <br /> Standards were prepared from stock mixtures of neat reagent grade compounds from Chem <br /> Service Inc. For preparation of daily standards,a measured volume of the standard mixture <br /> was injected directly into the gas chromatograph. <br /> 4 <br />