Laserfiche WebLink
t <br />' TABLE 1 <br /> CUMULATIVE RESULTS OF LABORATORY ANALYSES OF GROUNDWATER SAMPLES <br /> Coca-Cola Former Distribution Facility <br /> 1100 North Wilson Way <br />' Stockton,California <br /> (Page 2 of 2) <br /> Well Date a T E X TPHd TPHS Total <br />' Number Sampled Lead <br /> MW-6 11/08/90 ND ND ND ND 64 ND NA <br /> 12/06/90 ND 066 ND 037 ND ND NA <br />' 03/18/91 ND ND ND 042 ND 79 22 <br /> 05/22/91 065 ND ND ND ND ND ND <br /> 08/22/91 ND ND ND ND 140 ND ND <br /> 11/21/91 ND ND ND ND ND ND ND <br />' 12/17/92 ND ND ND ND ND ND NA <br /> 03/1I/93 ND ND ND ND ND 120 NA <br /> Reeulatory Limits <br />' MCLS 10 — 680 I,750 — -- 50 <br /> ALa -- 100 -- -- — -- — <br />' All results are in micrograms per liter or parts per billion(ppb) <br /> REFERENCE All results prior to November 1992 are based on data from USTEC reports referenced in this report <br /> TPHg Total Petroleum Hydrocarbons as Gasoline <br /> TPHd Total Petroleum Hydrocarbons as Diesel <br /> B,T,E,X Benzene,Toluene,Ethylbenzene,and Total Xylenes <br /> ND Not Detected <br /> NA Not Analyzed <br /> ` Organic Lead <br /> MCLS State of California and/or Federal Maximum Contaminant Levels in drinking water <br /> ALs State of California Action Lints in drinking water <br /> NS Not Sampled Pursuant to Agreement wuh San Ioaqurn County Public Health Services <br /> 1 <br /> I <br /> 1 <br />