Laserfiche WebLink
LqWD PROGRAM CONSOLIDATED FO9W <br /> TANKS <br /> UNDERGROUND STORAGE TANKS - TANK PAGE 2 <br /> P age of <br /> UNDERGROUND PIPING ABOVEGROUND PIPING <br /> SYSTEM TYPE 1.PRESSURE ❑2.SUCTION [13.GRAVITY 458. [11.PRESSURE 0 2.SUCTION 0 3.GRAVITY 459. <br /> CONSTRUCTION/ ❑ 1.SINGLE WALL ❑3.LINED TRENCH 0 99.OTHER 460. 0 1.SINGLE WALL [195.UNKNOWN 462. <br /> MANUFACTURER 2.DOUBLE WALL ❑95.UNKNOWN [12.DOUBLE WALL 0 99.OTHER <br /> MANUFACTURER Smith Fibercast 461 MANUFACTURER 463, <br /> ❑ 1.BARE STEEL 6.FRP COMPATIBLE W/100%METHANOL ❑1.BARE STEEL [16.FRP COMPATIBLE W/100%METHANOL <br /> ❑2.STAINLESS STEEL ❑7.GALVANIZED STEEL ❑2.STAINLESS STEEL D 7.GALVANIZED STEEL <br /> ❑3.PLASTIC COMPATIBLE WITH CONTENTS 0 95.UNKNOWN [3 3.PLASTIC COMPATIBLE W/CONTENTS [18,FLEXIBLE(HDPE) ❑99.OTHER <br /> ❑4.FIBERGLASS ❑8.FLEXIBLE(HDPE) [199.OTHER ❑4.FIBERGLASS D 9.CATHODIC PROTECTION <br /> ❑5.STEEL W/COATING ❑9.CATHODIC PROTECTION 464. ❑5.STEEL W/COATING ❑95.UNKNOWN 465. <br /> k';A4*riPtiP'ft oithe,midnjo ge,40y) <br /> UNDERGROUND PIPING ABOVEGROUND PIPING <br /> SINGLE WALL PIPING 466. SINGLE WALL PIPING 467. <br /> PRESSURIZED PIPING(Check all that apply): PRESSURIZED PIPING(Check all that apply): <br /> 0 1. ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TEST WITH AUTO PUMP [11. ELECTRONIC LINE LEAK DETECTOR 3.0 GPH TEST WITH AUTO PUMP <br /> SHUT-OFF FOR LEAK,SYSTEM FAILURE,AND SYSTEM DISCONNECTION SHUT OFF FOR LEAK,SYSTEM FAILURE,AND SYSTEM DISCONNECTION <br /> +AUDIBLE AND VISUAL ALARMS. +AUDIBLE AND VISUAL ALARMS. <br /> 0 2. MONTHLY 0.2 GPH TEST 02. MONTHLY 0.2 GPH TEST <br /> [13. ANNUAL INTEGRITY TEST(0.1 GPH) [13. ANNUAL INTEGRITY TEST(0.1 GPH) <br /> [14. DAILY VISUAL CHECK <br /> CONVENTIONAL SUCTION SYSTEMS CONVENTIONAL SUCTION SYSTEMS(Check all that apply) <br /> ❑5. DAILY VISUAL MONITORING OF PUMPING SYSTEM+TRIENNIAL PIPING [15. DAILY VISUAL MONITORING OF PIPING AND PUMPING SYSTEM <br /> INTEGRITY TEST(0.1 GPH) <br /> SAFE SUCTION SYSTEMS(NO VALVES IN BELOW GROUND PIPING): [16. TRIENNIAL INTEGRITY TEST(0.1 GPH) <br /> 0 7. SELF MONITORING SAFE SUCTION SYSTEMS(NO VALVES IN BELOW GROUND PIPING): <br /> GRAVITY FLOW [17. SELF MONITORING <br /> 09. BIENNIAL INTEGRITY TEST(0.1 GPH) GRAVITY FLOW(Check all that apply): <br /> [18. DAILY VISUAL MONITORING <br /> [19. BIENNIAL INTEGRITY TEST(0.1 GPH) <br /> SECONDARILY CONTAINED PIPING SECONDARILY CONTAINED PIPING <br /> PRESSURIZED PIPING(Check all that apply): PRESSURIZED PIPING(Check all that apply): <br /> 10. CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL 10. CONTINUOUS TURBINE SUMP SENSOR WITH AUDIBLE AND VISUAL <br /> ALARMS AND(Check one) ALARMS AND(Check one) <br /> a. AUTO PUNT SHUT OFF WHEN A LEAK OCCURS 0 a. AUTO PUMP SHUT OFF WHEN A LEAK OCCURS <br /> b. AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE AND SYSTEM [I b.AUTO PUMP SHUT OFF FOR LEAKS,SYSTEM FAILURE AND SYSTEM <br /> DISCONNECTION DISCONNECTION <br /> [3c. NO AUTO PUMP SHUT OFF [3c. NO AUTO PUM]?SHUT OFF <br /> 011. AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST)WITH FLOW SHUT ❑11. AUTOMATIC LEAK DETECTOR <br /> OFF OR RESTRICTION <br /> 012. ANNUAL INTEGRITY TEST(0.1 GPH) ❑12. ANNUAL INTEGRITY TEST(0.1 GPH) <br /> SUCTION/GRAVITY SYSTEM SUCTION/GRAVITY SYSTEM <br /> [113. CONTINUOUS SUMP SENSOR+AUDIBLE AND VISUAL ALARMS [113, CONTINUOUS SUMP SENSOR+AUDIBLE AND VISUAL ALARMS <br /> EMERGENCY GENERATORS ONLY(Check all that apply) EMERGENCY GENERATORS ONLY(Check all that apply) <br /> 014. CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF ❑14. CONTINUOUS SUMP SENSOR WITHOUT AUTO PUMP SHUT OFF <br /> AUDIBLE AND VISUAL ALARMS AUDIBLE AND VISUAL ALARMS <br /> 015. AUTOMATIC LINE LEAK DETECTOR (3.0 GPH TEST) WITHOUT FLOW ❑ 15. AUTOMATIC LINE LEAK DETECTOR(3.0 GPH TEST) <br /> SHUT OFF OR RESTRICTION <br /> [116. ANNUAL INTEGRITY TEST(0.1 GPH) ❑16. ANNUAL INTEGRITY TEST(0.1 GPH) <br /> Cj 17. DAILY VISUAL CHECK D 17. DAILY VISUAL CHECK <br /> VIU:DISI' SERI CONTAINNO" <br /> DISPENSER CONTAINMENT 468. ❑1. FLOAT MECHANISM THAT SHUTS OFF SHEAR VALVE ❑4. DAILY VISUAL CHECK 469. <br /> DATE INSTALLED 0 2. CONTINUOUS DISPENSER PAN SENSOR+AUDIBLE AND VISUAL ALARMS 05. TRENCH/LINER MONITORING <br /> 2005 0 3. CONTINUOUS DISPENSER PAN SENSOR WITH AUTO SHUT OFF FOR 06. NONE <br /> DISPENSER+AUDIBLE AND VISUAL ALARMS <br /> I certify that the information pr vide to the best of my knowledge. <br /> SIGNATURE OF OWNER/O 0_�Oereinjs true and ac DATE: 4/18/05 470, <br /> NAME OF OWNER/OPERATOR(print): Michael E.Walton TITLE OF OWNER/OPERATOR: Contractor 472. <br /> Permit Number(Agency use only) 473. 1 Permit Approved By(Agency use only) 474. 1 Permit Expiration Date(Agency use only) 475. <br /> UPCF hwfwre-b(1/99)-3/4 http://www.unidoes.org Rev.02/16/00 <br />