COMPLIANCE INFO_2010-2011
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
R
>
REYNOLDS RANCH
>
2680
>
2300 - Underground Storage Tank Program
>
PR0535432
>
COMPLIANCE INFO_2010-2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/11/2024 3:15:22 PM
Creation date
6/23/2020 6:39:20 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010-2011
RECORD_ID
PR0535432
PE
2351
FACILITY_ID
FA0020431
FACILITY_NAME
COSTCO WHOLESALE #1091
STREET_NUMBER
2680
STREET_NAME
REYNOLDS RANCH
STREET_TYPE
PKWY
City
LODI
Zip
95240
CURRENT_STATUS
01
SITE_LOCATION
2680 REYNOLDS RANCH PKWY
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2351_PR0535432_2680 REYNOLDS RANCH_2010-2011.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
395
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
-2 - <br /> ■ Is regulated by the State Department of Health Services (DHS); <br /> and <br /> ■ Is subject to the notification requirements for wells found to have <br /> contaminants in excess of maximum contaminant levels or action <br /> levels established by DHS. [Health & Saf. Code, § 25299.97, subd. <br /> (a)(1)] <br /> What is the deadline for performing ELD and how often does ELD have to be <br /> performed on a subject UST system? <br /> For UST systems with a single-walled component, ELD must be performed no later <br /> than 18 months following receipt of notification from the State Water Board and be <br /> repeated every thirty-six (36) months thereafter [Cal. Code Regs., Title 23, § 2644.1, <br /> subd. (a) (3)]. <br /> • What is a single-walled component?A single-walled component is any part of <br /> a LIST system that is constructed with walls made of only one thickness of <br /> material. Laminated, coated, or clad materials are all considered single-walled <br /> [Health & Saf. Code, § 25281, subd. (r)]. Tanks that were lined to meet the 1998 <br /> upgrade requirements are also considered to be single-walled. LIST systems with <br /> any of the following components are considered "single-walled": a single-walled <br /> tank, single-walled pressurized piping, single-walled conventional suction piping, <br /> a dispenser without under-dispenser containment, or a turbine that is not <br /> contained in a sump. However, single-walled vent or tank riser piping, vapor <br /> recovery piping, and "safe" or"European" suction piping are not considered <br /> single-walled components of UST systems if they meet the definition of section <br /> 2636 (a)(1), (2), or (3) [Cal. Code Regs., Title 23, § 2640, subd. (e)(1)]. LIST <br /> systems with a single-walled component were typically installed on or before <br /> January 1, 1984, although some may have been installed between January 1, <br /> 1984 and July 1, 1987. <br /> For UST systems with secondary containment that were installed before July 1, 2003 <br /> and are located within 1,000 feet of a public drinking water well, one-time ELD testing is <br /> required [Health & Saf. Code, §25292.5, subd. (a)]. <br /> • What is an LIST system with secondary containment?An UST system with <br /> secondary containment has a second containment around all regulated single- <br /> walled components. An UST system with secondary containment at a minimum <br /> includes all of the following: a double-walled tank, double-walled piping (unless <br /> piping is "safe" or"European" suction), a turbine containment sump and under- <br /> dispenser containment. LIST systems that meet the criteria of secondary <br /> containment were typically installed after July 1, 1987, although some may have <br /> been installed between January 1, 1984 and July 1, 1987. <br /> In addition, Health and Safety Code, §25289, subdivision (b) authorizes the State Water <br /> Board to require ELD testing when the State Water Board finds that the burden of the <br /> testing, including costs, bears a reasonable relationship to the need for the testing and <br /> reporting. The State Water Board finds that the burden of imposing required ELD testing <br /> of USTs located within 1000 feet of a public drinking water well on owners or operators <br /> California Environmental Protection Agency <br /> C,,*Recycled Paper <br />
The URL can be used to link to this page
Your browser does not support the video tag.