COMPLIANCE INFO_2010-2011
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
R
>
REYNOLDS RANCH
>
2680
>
2300 - Underground Storage Tank Program
>
PR0535432
>
COMPLIANCE INFO_2010-2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/11/2024 3:15:22 PM
Creation date
6/23/2020 6:39:20 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010-2011
RECORD_ID
PR0535432
PE
2351
FACILITY_ID
FA0020431
FACILITY_NAME
COSTCO WHOLESALE #1091
STREET_NUMBER
2680
STREET_NAME
REYNOLDS RANCH
STREET_TYPE
PKWY
City
LODI
Zip
95240
CURRENT_STATUS
01
SITE_LOCATION
2680 REYNOLDS RANCH PKWY
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2351_PR0535432_2680 REYNOLDS RANCH_2010-2011.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
395
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Note: Enhanced Leak Detection (ELD) must be performed prior to the final inspection. <br /> A separate hermit application is required to install ELD. <br /> 2. TO RE SUIIMITTED PRIOR TO THE FINAL INSPECTION.- <br /> El <br /> NSPECTION.❑ Complete to scale As-Built Plans <br /> �G <br /> 3�Vb L( Complete Monitoring and Response Plan <br /> ❑ UPCF Underground Storage Tanks - Installation Certificate of Compliance (one fors <br /> er tank <br /> ❑ Completed Underground Storage Tank Certification of Financial Responsibility form <br /> along with any required attachments <br /> ❑ Passing Line Leak Detector Test Results <br /> Passing Line Tightness Test Results (Required if the UST system does not satisfy the <br /> California Code of Regulations 2636(8) for automatic pump shut-off.) <br /> A Passim; Enhanced Leak Detection Results <br /> D. INSPECTIONS: <br /> Nole: .4 1-el)reveliluli►•e.fi-om the Sari.luaytiiii CoinrtvEn►,ii-villnetital Health Depai•iilieiil <br /> i11NSl 1441/1' all aclivilies tlevci-ihecl Mow. <br /> Tank holiday test (for fiberglass-coated steel tanks) performed prior to installation in <br /> excavation <br /> inspection of tank vacuum gauge (if applicable)prior to placement in excavation <br /> (-2,2 (� /a Tank soap test (for fiberglass tanks)performed prior to installation in excavation <br /> '-Z-0Verification of tank set and anchorage in excavation <br /> Primary piping including product piping, vapor recovery and vent line piping soap and <br /> pressure test <br /> ALI <br /> Secondary piping including product piping, vapor recovery and vent line piping soap <br /> l and pressure test <br /> 24-Hour secondary containment lake test on sumps and under-dispenser containment <br /> Piping Slope& cathodic protection prior to covering <br /> Overfill perforniance test 14� dw/�- <br /> '1,' Prior to receiving fuel, a complete functional test of tank and piping monitoring <br /> system(s) including overfill prevention Sa V- *01- S-1A,(I <br /> ❑ Final inspection and demonstration of automatic shut down (if applicable). <br /> Revised 08/06/09�1 ��� 5 <br /> v 14573.006.pdf <br />
The URL can be used to link to this page
Your browser does not support the video tag.