My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2016-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CLAY
>
655
>
2300 - Underground Storage Tank Program
>
PR0231065
>
COMPLIANCE INFO_2016-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/9/2022 11:53:15 AM
Creation date
6/23/2020 6:40:10 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016-2018
RECORD_ID
PR0231065
PE
2361
FACILITY_ID
FA0003699
FACILITY_NAME
DSS COMPANY
STREET_NUMBER
655
Direction
W
STREET_NAME
CLAY
STREET_TYPE
ST
City
STOCKTON
Zip
95206
APN
14707110
CURRENT_STATUS
01
SITE_LOCATION
655 W CLAY ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231065_655 W CLAY_.tif
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
106
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ImW <br /> San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209)468-3420 Fax:(209)468-3433 Web:www.sjgov.or /q ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> DSS COMPANY 1 655 W CLAY ST STOCKTON July 12 2016 <br /> UST System Observations <br /> 326 CCR 2631.1 UST system not compatible with the substance stored ❑V ❑R ❑COS <br /> 327 HSC 25298(b) Failed to comply with temporary closure requirements ❑V ❑R ❑COS <br /> 328 HSC 25298(c) Failed to comply with permanent closure requirements ❑V ❑R ❑COS <br /> 329 CCR 2636(f)(6) Failure to meet all requirements in lieu of a line leak detector for emergency generator tank system ❑V ❑R ❑COS <br /> Non-Pressurized Piping <br /> 401 CCR 2636(a)(3) Suction piping not properly sloped or incorrectly located check valve ❑V ❑R ❑COS <br /> 402 CCR 2643(d) Daily monitoring of suction pipe(pre-Jan 1984)not performed ❑V ❑R ❑COS <br /> 403 CCR 2643(d) Triennial 0.1 gph line test for conventional suction piping not performed(pre-January 1984) ❑V ❑R ❑COS <br /> 404 CCR 2643(e) Biennial 0.1 gph test for gravity piping not performed(pre-January 1984) ❑V ❑R ❑COS <br /> Other Violations <br /> 2010 See below Unlisted Administration/Documentation violation ❑V ❑R ❑COS <br /> 2030 See below Unlisted Operations/Maintenance violation ❑V ❑R ❑COS <br /> 2060 See below Unlisted Design/Construction violation ❑V ❑R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 104 CCR 2711 UST Operating Permit Application for Facility and Tank information not submitted or current. <br /> Underground storage tank(UST) Facility Operating Permit Application and UST Tank Information for TA0508341 are <br /> not current in CERS. <br /> The UST Facility Operating Permit Application lists the Board of Equalization (BOE) number as 44033511. According <br /> to the BOE website, the Account Number TK STF 44033511 is closed and not valid. Submit a valid BOE number <br /> immediately. <br /> The UST Tank information for UST TA0508341 does not list any corrosion protection. Determine the corrosion <br /> protection for this tank and enter"yes" for the appropriate corrosion protection in CERS. Any change of information <br /> must be updated in CERS within 30 days of the changes. Immediately log into CERS, update the required <br /> information, and submit for review by the EHD. <br /> This is a Class II violation. <br /> 105 CCR 2632 Monitoring and response plans not current or approved by the EHD. <br /> The UST Monitoring Plan is not accurate in CERS. Below"Recordkeeping"change 'No' to'Yes' for Visual Inspection <br /> Records. Any change of information must be updated in CERS within 30 days of the changes. Immediately log into <br /> CERS, update the required information, and submit for review by the EHD. <br /> This is a repeat violation, Class II. <br /> Page 3 of 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.