Laserfiche WebLink
14 7-11 # 20632 4672 DAVINCI DR . STOCKTON CALIF. .-P 4/26/92 <br /> Name of Supplier.Owner or Dealer Address No.and Street(s) City State Date of Test <br /> 15. TANK TO TEST 15a. BRIEF DIAGRAM OF TANK FIELD 16. CAPACITY From <br /> ❑ Station Chart <br /> NORTH SOUTH Nominal Capacity 107000 ❑ Tank Manufacturer's Chart <br /> Identity by position Gallons ® Company Engineering Data <br /> MID GRADEBy most accuchart L1Charliesupplied with Tank Tester <br /> Brand and Grade capacity chart available <br /> 9980 ailable ❑ Other <br /> Gallons <br /> Total Gallons <br /> 17. FILL-UP FOR TEST ea.Reading <br /> Stick Water Bottom Inventory in Tank 9980 <br /> before Fill-up 0/In. 95 in. <br /> to%" Gallon Tank Diameter Water Bottom /�( <br /> _ X� <br /> 18. SPECIAL CONDITIONS AND PROCEDURES TO TEST THIS TANK ❑Water in lank ❑ Line(s)being tested with LVLLT Top off equipment + <br /> See manual sections applicable.Check below and record procedure In tog(27). E]Highwater table in tank excavation Total°uantity 9990 <br /> n <br /> Lee maximum allowable teat pressure for all tests. 19. TANK MEASUREMENTS FOR <br /> Four pound rule does not apply to doublewalled tanks. <br /> TSTT ASSEMBLY 21. VAPOR RECOVERY SYSTEM M* Stage I Stage It <br /> Complete section below: 136 in <br /> Bottom of tank to grade' ............................ <br /> Add 30"for'T'probe easy........................... - 30 in. 24b. COEFFICIENT OF EXPANSION <br /> f. is four pound rule required? Yale ❑ NO ❑ Total tubing to assemble—approximate............. in. RECIPROCAL METHOD MID Type of Product................................MID GRADE <br /> 2.Height roIYmark from grade 47 in. 20. EXTENSION HOSE SETTING 416 N <br /> Tank top to grade'.................................. in. Hydrometer Employed.................................. <br /> Extend hose on suction tube 6"or more Temperature In Tank •9 <br /> 3. Pressure at bottom of lank -4- 76 P.S.I. After Circulation.........I.............................. 67- <br /> •F <br /> belowlank top...................................... In. <br /> Temperature of Sample................................. 51 •F <br /> 4. Pressure at top of tank 2 . 7 A P.S.I. 'If Fill pipe extends above grade,use top of fill. —1 6 F <br /> USE WITH THERMAL SENSOR Difference(•-)......................................... • <br /> Depth of burial 13 6 in. PN5O39(Blue Box) Observed A.P.I.Gravity ................................. 53.4 <br /> 22. Thermal-Sensor reading after circulation 1519 5 7 <br /> r�C digits Reciprocal Pape e <br /> Tank dls. 3-d i^. °F <br /> Between 9990 1519 . 6. 5766951 <br /> 23. Digits per•F in range of expected change Total quantity in Reciprocal Volume change in <br /> digits full tank(17) this tank per•F <br /> Water table to tank bottom 1 i^• Transfer to Line 26s. <br /> NOTES: <br /> C4. 756 <br /> ! . 36== . 756 ®24a. IF USING THERMAL SENSOR DTS-2000 <br /> 6+ 4=4. 756 OR OC-2O00 WHICH READ 1000 DIGITS <br /> 24c. FOR TESTING WITH WATER ,..T.bl.cao <br /> , .026= 182.9 PER eF TRANSFER 1000 TO LINE 26, <br /> — 36= 47" Water Temperature after Circulation <br /> DIGITS PER eF IN TEST RANGE. TableCfromThermalSensor............................ F <br /> TE 47" TO 1201 MARK <br /> 67. 750 coefficient of Water <br /> The above calculations are to be used for dry soil conditions to Table D................................................ <br /> establish a positive pressure advantage•or when using the four pound <br /> rule to compensate for tiro presence of subsurface water In the tank Added Surfactant? ❑Yes ❑No Transfer COE to Line 25b. <br /> area. /'' I <br /> Refer to N.F.P.A. 30, Sections 2-3.2.4 and 2-7.2 and the tank 25• x �b) � (0 gallons <br /> manufacturer regarding allowable system test pressures. Total quantity in Coefficient of expansion for Volume change in this tank <br /> full tank(f7) involved product per•F - - <br /> 26. <br /> (a) 6. 5766951 11000 _ .0065766 This is .0066 <br /> Volume change per•F(25 or 24b) Digits per-F in test Volume change per digit test <br /> Range(23 or 24a) Compute to 4 decimal places. factor(a) <br />