COMPLIANCE INFO_1998-2002
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
D
>
DA VINCI
>
4627
>
2300 - Underground Storage Tank Program
>
PR0231074
>
COMPLIANCE INFO_1998-2002
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/1/2023 9:51:39 AM
Creation date
6/23/2020 6:40:56 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1998-2002
RECORD_ID
PR0231074
PE
2361
FACILITY_ID
FA0002541
FACILITY_NAME
7-ELEVEN INC #20632
STREET_NUMBER
4627
STREET_NAME
DA VINCI
STREET_TYPE
DR
City
STOCKTON
Zip
95207
APN
11002003
CURRENT_STATUS
01
SITE_LOCATION
4627 DA VINCI DR
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231074_4627 DA VINCI_1998-2002.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
341
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
"OPW 10 SER_J*S EMERGENCY <br />5'#T-OFF <br />VALVES <br />The 10 Series Emergency Shut -Off <br />Valves feature a combination body <br />which includes both u -bolt and stabiliz- <br />er bar mounting options, a low profile <br />design and a secondary poppet hold - <br />open bridge. These features make the <br />10 Series the most versatile, secure and <br />convenient line of emergency shut-off <br />valves on the market today. <br />The OPW 10 Series Valves mount <br />within the pedestal on fuel lines at <br />island surface level. In the event the <br />pedestal is dislocated or overturned, the <br />OPW 10 Series is designed to break at <br />the shear groove. When properly <br />installed, the top section shears off, <br />causing the valve to close, preventing <br />gasoline spillage and -reducing the <br />likelihood of a potentially hazardous <br />condition. <br />The OPW 10 Series Valves are <br />designed to handle today's methanol <br />fuel blends such as M-85 and M-100. <br />All OPW 10 Emergency Shut-off <br />Valves meet the requirements of UL <br />STANDARD 842. <br />Important Notice: When mounting the <br />OPW 10 Series Emergency Shut-off <br />Valves, the anchoring device employed <br />must withstand a force greater than 650 <br />ft. pounds per valve. Both u -bolt and <br />stabilizer bar hardware kits are provid- <br />ed with each valve. <br />Standard Features: <br />♦ Combination Body - The 10 Series <br />Emergency Shut-off Valves offer the <br />versatility of a combination body for <br />added convenience and security. <br />This feature allows u -bolt or stabi- <br />lizer bar mounting, thereby reducing <br />the dangers of forcing inappropriate <br />mounting. <br />♦ Low Profile Design - The 10 Series <br />Double Poppet Emergency Valves' <br />internally threaded and union <br />designs are the same height as the <br />single poppet versions, allowing eas- <br />ier installation when upgrading an <br />existing site or installing a new site, <br />with the added security of a second <br />poppet. <br />♦ Hold -Open Bridge - The hold -open <br />bridge holds the secondary poppet <br />open to reduce product flow <br />restriction. <br />♦ Low Pressure Loss - On all OPW <br />10 Series Valves, the primary poppet <br />is out of the flow area, giving <br />straight -through, free flow of prod- <br />uct. On double poppet styles, the <br />hold -open bridge holds the sec- <br />ondary poppet open to reduce prod- <br />uct flow restriction. <br />♦ Built -In Air Test Port - Allows <br />pneumatic testing of the entire <br />pumping system, without breaking <br />the line, after installation is com- <br />plete. <br />♦ Fusible Link - Releases at 165°F in <br />the event of a fire, allowing the <br />valve to automatically close, thereby <br />reducing fire hazard. <br />♦ Main Seat In The Top Assembly <br />Assures A New Seating Surface <br />Each Time The Valvetop Is <br />Replaced - Improving performance <br />and extending valve service life. <br />(OPW recommends that the electri- <br />cal supply to the pump associated <br />with an emergency valve be turned <br />off during valve or meter service.) <br />Additionally, this feature ensures the <br />seal between the top and the valve <br />body is tested during line testing and <br />allows full inspection of the main <br />poppet whenever the top is changed. <br />Unique Features: <br />♦ Discs and seals are made of OPW's <br />special Compound M-19. This forti- <br />fied elastomer improves the valve's <br />resistance to alcohol enhanced fuels. <br />♦ NFPA code 30A, Automotive and <br />Marine Service Station Code, <br />requires that the automatic closing <br />feature of emergency shut-off valves <br />be checked at least once per year by <br />manually tripping the hold -open <br />linkage. The OPW 10 Series Valves <br />incorporate several unique features <br />that, together with regular inspection <br />procedures, help promote consistent <br />operation. <br />• Stainless-steel main spring <br />• Copper -nickel -chrome plated <br />brass stem <br />• Teflon® coated packing nut <br />♦ Unique black Duragard® coating <br />provides extra corrosion protection <br />and easy identification. <br />♦ OPW IOBP Series is designed with <br />a secondary poppet to help contain <br />product within the dispenser and <br />features low pressure loss for effi- <br />cient fuel delivery. The patented <br />integral thermal relief valve helps <br />prevent system pressure build-up <br />due to thermal expansion. <br />♦ All OPW 10 Series Valves are <br />shipped with straight bolts and a <br />u -bolt in order to accommodate both <br />bolting options. <br />♦ Listed by Underwriters Laboratories <br />Inc. for use with gasoline and 85% <br />and 100% methanol. U� <br />.�„ Telephone: (513) 810-3219 . (800)422.2525. Fax: (513)810-9186 • (800) 421-3297 r <br />01997 OPW Fueling Components • P.O. Box 405003.Oncinneti, Ohio 45240-5003 • Printed In USA . TFl0.4/97 <br />
The URL can be used to link to this page
Your browser does not support the video tag.