My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1998-2002
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
D
>
DA VINCI
>
4627
>
2300 - Underground Storage Tank Program
>
PR0231074
>
COMPLIANCE INFO_1998-2002
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/1/2023 9:51:39 AM
Creation date
6/23/2020 6:40:56 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1998-2002
RECORD_ID
PR0231074
PE
2361
FACILITY_ID
FA0002541
FACILITY_NAME
7-ELEVEN INC #20632
STREET_NUMBER
4627
STREET_NAME
DA VINCI
STREET_TYPE
DR
City
STOCKTON
Zip
95207
APN
11002003
CURRENT_STATUS
01
SITE_LOCATION
4627 DA VINCI DR
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231074_4627 DA VINCI_1998-2002.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
341
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MONITORING SYSTEM CERTIFICATION <br /> '"' AM For Use By All Jurisdictions WRhin the State of Calofmi <br /> Authority Chapter 6.7,Health and Safety Code;Chapter 16,Divisio tle 23,California Code of Regulations <br /> This Form must be used to document testing and servicing of monitoring equipment. If more than one monitoring system control panel is insalled at the facility, a separate <br /> certification or report must be prepared for each monitring system control panel by the technician who performs the work. A copy of this form must be provided to the tank <br /> system owner operator. The owner operator must submit a copy of this form tot the local agency regulating UST systems within 30 days of test date. Instructions are printed <br /> on the back page. <br /> A. General Information <br /> Facility Name: 7-ELEVEN#20632 MKT 2237 <br /> Site Address: 4627 DA VINCI DR. City: STOCKTON CA Zip:95207 <br /> @ MARCH LN. Contact Phone No: 952-3543 <br /> Facilty Contact Person: MGR-SATBIR Date of Testing/Service: 06/25/2001 <br /> Make/Model of Monitoring System:VR TLS350R Word Order Number: 2217378 <br /> B.Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to Indicate specific equipment inspected/serviced <br /> Tank ID: 1 Tank ID: 2 <br /> -59 In-Tank Gauging Probe. Model: 847390107 71 In-Tank Gauging Probe. Model: 847390107 <br /> 71 Annular Space or Vault Sensor. Model: 794390420 71 Annular Space or Vault Sensor. Model: 794390420 <br /> 71 Piping Sump/Trench Sensor(s). Model: 794380352 71 Piping Sump/Trench Sensor(s). Model: 794380352 <br /> Fill Sump Sensor(s). Model: Fill Sump Sensor(s). Model: <br /> 71 Mechanical Line Leak Detector. Model: LD2000 Mechanical Line Leak Detector. Model: LD2000 <br /> Electronic Line Leak Detector. Model: Electronic Line Leak Detector. Model: <br /> ,71 Tank Overfill/High-Level Sensor. Model: 61 SO 71 Tank Overfill/High-Level Sensor. Model: 61 SO <br /> Dispenser Containment Sensor(s) Model: 794380352 Model: 794380352 <br /> -39 p Dispenser Containment Sensor(s) <br /> Shear Valve(s). 71 Shear Valve(s). <br /> Dispenser Containment Float(s)and Chains(s). Dispenser Containment Float(s)and Chains(s). <br /> Other(specify equipment type and model in Section E on page 2). Other(specify equipment type and model in Section E on page 2). <br /> an 15HRID: <br /> In-Tank Gauging Probe. Model: In-Tank Gauging Probe. Model: <br /> Annular Space or Vault Sensor. Model: 7Annular Space or Vault Sensor. Model: <br /> Piping Sump/Trench Sensor(s). Model: Piping Sump/Trench Sensor(s). Model: <br /> Fill Sump Sensor(s). Model: Fill Sump Sensor(s). Model: <br /> Mechanical Line Leak Detector. Model: Mechanical Line Leak Detector. Model: <br /> Electronic Line Leak Detector. Model: Electronic Line Leak Detector. Model: <br /> Tank Overfill/High-Level Sensor. Model: Tank Overfill/High-Level Sensor. Model: <br /> Dispenser Containment Sensor(s). Model: Dispenser Containment Sensor(s). Model: <br /> Dispenser Containment Sensor(s). Model: Dispenser Containment Sensor(s). Model: <br /> Shear Valve(s). Shear Valve(s). <br /> Dispenser Containment Float(s)and Chains(s). Dispenser Containment Float(s)and Chains(s). <br /> Other(specify equipment type and model in Section E on page 2). Other(specify equipment type and model in Section E on page 2). <br /> C. Certification <br /> /certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturer's guidelines. <br /> Attached to this certification is information(e.g manufacturer's checklists)necessary to verify that this information is correct <br /> and a Site Plan showing the layout of monitoring equipment.For any equipment capable of generating such reports,1 have also attached <br /> a copy of the(Check all that apply): System set-up report; ® Alarm history report <br /> PRINTED NAME: JEFF CONGER SIGNATURE: <br /> COMPANY: Tanknology PHONE NO: (800)800-4633 <br /> page 1 of 3 Based on CA form dated 05/00 <br />
The URL can be used to link to this page
Your browser does not support the video tag.