My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1998-2002
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
D
>
DA VINCI
>
4627
>
2300 - Underground Storage Tank Program
>
PR0231074
>
COMPLIANCE INFO_1998-2002
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/1/2023 9:51:39 AM
Creation date
6/23/2020 6:40:56 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1998-2002
RECORD_ID
PR0231074
PE
2361
FACILITY_ID
FA0002541
FACILITY_NAME
7-ELEVEN INC #20632
STREET_NUMBER
4627
STREET_NAME
DA VINCI
STREET_TYPE
DR
City
STOCKTON
Zip
95207
APN
11002003
CURRENT_STATUS
01
SITE_LOCATION
4627 DA VINCI DR
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231074_4627 DA VINCI_1998-2002.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
341
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
INDIVIDUAL I®UAL B NK INFORMATION N ■ ES ■ RESULTS <br /> ,60 ■ <br /> knology <br /> TEST DATE:05/09/00 8900 SHOAL CREEK,BUILDING 200 WORK ORDER NUMBER2211991 <br /> CLIENT:7-ELEVEN, INC. AUSTIN,TEXAS 78757(512)451-6334 SITE:7-ELEVEN #20632 <br /> Tank ID: 3 Tank manifolded: No Bottom to top fill in inches: <br /> Product: REG UNLEAD Vent manifolded: No Bottom to grade in inches: <br /> Capacity in gallons: 10,019 Vapor recovery manifolded: YES Fill pipe length in inches: <br /> Diameter in inches: 95.00 Overfill protection: YES Fill pipe diameter in inches: <br /> Length in inches: 330 Overspill protection: YES Stage I vapor recovery: COAX <br /> Material: Dw STEEL Installed: ATG Stage II vapor recovery: ASSIST <br /> CP installed on: <br /> COMMENTS <br /> Start(in) End(in) <br /> Dipped Water Level: New/passed Failed/replaced New/passed Failed/replaced <br /> Dipped Product Level: L.D.#1 L.D.#1 L.D.#2 L.D.#2 <br /> Probe Water Level: Make: <br /> Ingress Detected: Water Bubble Ullage Model: <br /> Test time: S/N: <br /> Inclinometer reading: Open time in sec: <br /> Holding psi: <br /> VacuTect Test Type: NOT Resiliency cc: NOT NOT <br /> VacuTect Probe Entry Point: TESTED TESTED TESTED <br /> Test leak rate mUm: <br /> Pressure Set Point: Metering psi: <br /> Tank water level in inches: Calib. leak in gph: <br /> Water table depth in inches: Results: <br /> Determined by(method): <br /> Result: <br /> COMMENTS <br /> COMMENTS <br /> Material: ENVIROFLEX <br /> Diameter(in): 2.0 <br /> Length(ft): 10.0 <br /> Test psi: <br /> Bleedback cc: <br /> Test time(min): NOT NOT NOT NOT <br /> Start time: TESTED TESTED TESTED TESTED <br /> End time: <br /> Final gph: <br /> Result: <br /> Pump type: PRESSURE <br /> Pump make: RED JACKET <br /> COMMENTS Impact Valves Operational: <br /> Printed 05/17/2000 08:34 <br />
The URL can be used to link to this page
Your browser does not support the video tag.