Laserfiche WebLink
URBK 5/6 SDP Repair Instructions <br /> W.: <br /> for Shallow Dispenser Pans (con't) <br /> STEP 4 <br /> • Wrack the new repair boot around the pipe. <br /> • If needed,move the upper insert out of the way <br /> • Solvent weld using Zip-Tite- <br /> • Use 2 band clamps to hold boot together while curing. <br /> Step 6 STEP 7 <br /> Slide metal ring over the repair install the flange nuts and snug to <br /> boot and then over the studs pan floor. <br /> • Slide down the upper insert into the <br /> STEP 5 top of the repair boot. <br /> • Apply"sealer'to pan floor&bottom of Install band clamps&tighten. <br /> boot. y DO NOT exceed 60 inch pounds of <br /> • Rotate the fill port on the repair boot torque. <br /> for easy access <br /> • Then set the repair,boot over the studs-.- <br /> 7�- <br /> TOOLS REQUIRED: FILL Volume: (per repair boot) <br /> STEP 8 Gloves and Static Mixer If using 1.5"Pipe <br /> Fill boot with DBF 11. 5/16"Nut driver(Band Clamps) Volume of DBF 11 needed = 4 Oz <br /> dr Nut-24 <br /> 1 needed= I Oz <br /> 0 driver(Flange nuts) Volume of Zip Tite <br /> DAG Caulk Gun(for DRP&DBF 11) Volume of DBB V needed = 1 Oz <br /> DAG III Caulk Gun(for DBB V) Volume of DRP needed = 1 Oz <br /> I <br /> PRODUCTS NEEDED: f using 2"Pipe <br /> DBC Cleaner Volume of DBF 11 needed = 1 Oz <br /> Zip-nte Solvent Welding Liquid Volume of Tip Tite needed= 1 Oz <br /> DBF 11 Polysulficle Liquid volume of DBBV needed = 10z <br /> DRP Polysulfide Paste(for Poly Sumps] Volume of DRP needed = 10z <br /> DBB V Bonder(for Fiberglass sumps) <br /> Diversified Products Manufacturing Inc.Environ Repair Manual Full Version Rev 3 Page 60 of 70 <br />