My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2009-2012
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
D
>
DA VINCI
>
4627
>
2300 - Underground Storage Tank Program
>
PR0231074
>
COMPLIANCE INFO_2009-2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/1/2023 11:20:58 AM
Creation date
6/23/2020 6:41:02 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009-2012
RECORD_ID
PR0231074
PE
2361
FACILITY_ID
FA0002541
FACILITY_NAME
7-ELEVEN INC #20632
STREET_NUMBER
4627
STREET_NAME
DA VINCI
STREET_TYPE
DR
City
STOCKTON
Zip
95207
APN
11002003
CURRENT_STATUS
01
SITE_LOCATION
4627 DA VINCI DR
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231074_4627 DA VINCI_2009-2012.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
434
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
From: (949)460-5204 To: 12094683433 Page:4/7 Date: 9/20/2010 9:06:38 AM <br /> i-rom:' Hage:W4 hate:WIr2uri u I IM HM <br /> HOW TO LOCATE THE POSITION OF THE <br /> 7180 AT 95%TANK CAPACITY Measuring stick <br /> The length of the upper tube and the placement of -------'" <br /> the 71 SO valve body determine the shut-off point. <br /> Following the standard instructions for the OPW <br /> 71 SO will provide for initial shutoff at 95%. In all <br /> cases,the upper tube length must be a minimum of <br /> 6-1/2"plus the length of the riser pipe. All length <br /> measurements are in inches. Riser Pipe <br /> with Face <br /> INSTRUCTIONS Seal Adaptor TaTank (S) <br /> 1.)Find tank capacity(fn gallons)from tank Top(I-D-) To Tank <br /> calibration dart provided by tank manufacturer. Bottom <br /> 2.)Calculate 95%of capacity. <br /> 3.)Locate the 95%volume number on the tank <br /> calibration chart. <br /> 4.)Find the dipstick number(X)which corresponds Figure 1 <br /> to the 95%tank volume. And,find the dipstick <br /> number(1)which corresponds to the EXAMPLE <br /> 100%volume. 1.)For an Owens-Coming Model G-3 Fiberglass@ <br /> Subtract the d tick number }from the tank Tank Calibration Chart: <br /> 5. <br /> � � Tank Capacity-10000 gal.,nominal 9,443 gat. <br /> diameter(Y)to find the upper tune reference NOTL use actual capstAy only <br /> number(Z). <br /> (Y)-(X}=(Z) 2.)95%of actin tank cmadty=0.95 x <br /> 9403 gal.=8833 gal. <br /> 6.)Subtract 2"from(Z)to find the upper tube depth <br /> (C). 3.)The closest number which is less than 8933 gal. <br /> (Z)-2"=C Is 8910 gal.Choosing the closest number less <br /> than 95%of actual capacity ensures that the <br /> 7.)Is C less than 6-1/2"? Initial shutoff will occur when the tank is no more <br /> than 95%full. <br /> ._..._..Uppertube-leNdvis-C.plus-the..distaxcce-....... ._...__._.._..--- --- ------..._._._.. _..._............._..._............_................._..__..__....- _...._...._...._.._._.. _. <br /> from the top of the Face Seal Adaptor 4.)The calibration chart reading of 8910 gal. <br /> installed on the riser pipe to the inside,top corresponds to a dipstick measurement of 82". <br /> lip of the storage(A). <br /> 5.) Dipstick number(X)=82" <br /> Upper Tube Length=C+(A) Tank d'mameter(Y)=92" <br /> (Y)-(X)=(Z) (92"-82"=10") <br /> YES Upper tube length Is 6-112"plus the riser (Z)=10" <br /> pipe measurement(A). <br /> 6.) (Z)-2"=C (10"-2"=8") <br /> Upper Tube Length=6-1/Z'+(A) C=8" <br /> NOTE: You must find the actual tank capacity 7,)Is 8"less than 6-1/2"? <br /> number that correlates to the 6.112"+(A)depth for <br /> the station records. this number may also be used No Measure fife distance from the top of the <br /> for the of calibrating an electronic tank FSA-400 Fare Seal Adaptor installed on the <br /> levet system riser pipe to the inside,top lip of the storage <br /> tank and obtain measurement(A). <br /> 0 Re&WW T.M.-Owens comms Fibergim Corporation <br /> Upper tube length=C+(A) <br /> OPW 7180 Overfill Prevention Valve Page 4 <br /> This fax was received by GFI FAXmaker fax server.For more information,visit hfp:imww.gfi.com <br /> This fax was sent with GFI FAXmaker fax server. For more information,visit: http://www.gfi.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.