Laserfiche WebLink
MONITORING SYSTEM CERTIFICATION <br /> F e By All Jurisdictions Within the State of CaliforniaAft <br /> Authority Cited:Chapter 6.7,HJWand Safety Code,Chapter 16,Division 3 Title 23, CWrnia Code of Regulations <br /> This form must be used to document testing and servicing of monitoring equipment. If more than one monitoring system control panel is installed at the facility,a separate <br /> certification or report must be prepared for each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank <br /> system owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A.General Information <br /> Facility Name: 7-ELEVEN#20632,MKT 2368 City: STOCKTON CA Zip:95207 <br /> Site Address: 4627 DA VINCI DR Contact Phone No: 952-3543 <br /> @ MARCH LN Date of Testing/Service: 02/17/2011 <br /> Facility Contact Person: MGR-SATBIR (PTO#N-748) <br /> Make/Model of Monitoring System:TLS 350R Work Order Number: 2279543 <br /> B.Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicate specific equipment inspected/serviced <br /> Tank ID: 1 RUL Tank ID: 2 PUL <br /> X In-Tank Gauging Probe. Model: MAG X1 In-Tank Gauging Probe. Model: MAG <br /> X Annular Space or Vault Sensor. Model: 420 21 Annular Space or Vault Sensor. Model: 420 <br /> X Piping Sump/Trench Sensor(s). Model: 208 7XPiping Sump/french Sensor(s). Model: 208 <br /> Fill Sump Sensor(s). Model: Fill Sump Sensor(s). Model: <br /> X Mechanical Line Leak Detector. Model: LD2000 X Mechanical Line Leak Detector. Model: LD2000 <br /> Electronic Line Leak Detector. Model: Electronic Line Leak Detector. Model: <br /> X Tank Overfill/High-Level Sensor. Model: FLAPPER Tank Overfill/High-Level Sensor. Model: FLAPPER <br /> Other(specify equipment type and model in Section E on page 2). Other(specify equipment type and model in Section E on page 2). <br /> TanklD: TanklD: <br /> In-Tank Gauging Probe. Model: DIn-Tank Gauging Probe. Model: <br /> Annular Space or Vault Sensor. Model: 7 Annular Space or Vault Sensor. Model: <br /> Piping Sump/Trench Sensor(s). Model: Piping Sump/Trench Senson s). Model: <br /> Fill Sump Sensor(s). Model: Fill Sump Sensor(s). Model: <br /> Mechanical Line Leak Detector. Model: Mechanical Line Leak Detector. Model: <br /> Electronic Line Leak Detector. Model: 7Electronic Line Leak Detector. Model: <br /> Tank Overfill/High-Level Sensor. Model: Tank Overfill/High-Level Sensor. Model: <br /> Other(specify equipment type and model in Section E on page 2). Other(specify equipment type and model in Section E on page 2). <br /> Dispenser : 1/2 Dispenser ID: 3/4 <br /> ®Dispenser Containment Sensor(s) Model:208 X Dispenser Containment Sensor(s) Model: 208 <br /> X�Shear Valve(s). X Shear Valve(s) <br /> ❑Dispenser Containment Float(s)and Chain(s). 7 Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: Dispenser lD: <br /> FIDispenser Containment Sensor(s) Model: Dispenser Containment Sensor(s). Model: <br /> F1 Shear Valve(s). Shear Valve(s). <br /> Dispenser Containment Float(s)and Chain(s). Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: Dispenser ID: <br /> nDispenser Containment Sensor(s) Model: Dispenser Containment Sensor(s). Model: <br /> Shear Valve(s). Shear Valve(s). <br /> 10 Dispenser Containment Float(s)and Chain(s). Dispenser Containment Float(s)and Chain(s). <br /> If the facility contains more tanks or dispensers,copy this form.Include information for every tank and dispenser at the facility. <br /> C. Certification <br /> I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers'guidelines. <br /> Attached to this certification is information(e.g manufacturers'checklists)necessary to verify that this information is correct. <br /> and a Site Plan showing the layout of monitoring equipment.For any equipment capable of generating such reports, I have also attached <br /> a copy of the(Check all that apply): IrT11 System set-up Alarm history report <br /> Technician Name(print): KRISTOPHER BELL Signature: <br /> Certification No.: B33709 License.NO.: 743160(Class'A'General Enginering Contractor License) <br /> Testing Company Name:Tanknology Phone No.: (800)800-4633 <br /> Site Address: 11000 N.MoPac Expressway,suite 500,Austin,TX 78759 Date of Testing/Servicing: 02/17/2011 <br /> Monitoring System Certification Page 1 of 3 Based on CA form dated 03/08 <br />