My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2009-2012
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
D
>
DA VINCI
>
4627
>
2300 - Underground Storage Tank Program
>
PR0231074
>
COMPLIANCE INFO_2009-2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/1/2023 11:20:58 AM
Creation date
6/23/2020 6:41:02 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009-2012
RECORD_ID
PR0231074
PE
2361
FACILITY_ID
FA0002541
FACILITY_NAME
7-ELEVEN INC #20632
STREET_NUMBER
4627
STREET_NAME
DA VINCI
STREET_TYPE
DR
City
STOCKTON
Zip
95207
APN
11002003
CURRENT_STATUS
01
SITE_LOCATION
4627 DA VINCI DR
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231074_4627 DA VINCI_2009-2012.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
434
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i J <br /> MONITORING SYSTEM CERTIFIDATION <br /> MAKE / MODEL OF MONITORING SYSTEM: Veeder-Root TLS-350 <br /> CERTIFICATION /TEST DATE: January 15, 2009 <br /> Al. FACILITY A2. OWNER <br /> Name 7-Eleven Market#2368/Store#20632 Name 7-Eleven, Inc <br /> Address 4627 DaVinci Ave,Stockton,CA 95207 Address P.O.Box 711,Dallas,TX 75221 <br /> Phone# 209-952-3543 Phone# 805-523-2949 <br /> Contact Jay Stemley Contact Shane Partridge <br /> A3. C U P A A4. TESTING CONTRACTOR <br /> Name San Joaquin County Environmental Health Name Walton Engineering, Inc. <br /> Address 600 E.Main Street,Stockton,CA 95202 Address P.O.Box 1025,W.Sacramento,CA 95691 <br /> Notified January 13,2009 Lic# 617238 A, B,Haz <br /> Inspector Garrett Backus Contact Richard Walton <br /> Phone# 209-468-3439 Phone# 916-825-3203 <br /> B. INVENTORY OF EQUIPMENT TESTED/CERTIFIED (Check the appropriate boxes to indicate equipment inspected/serviced) <br /> B1: TANKS <br /> Tank#1 (Product): Gasoline-87 Tank#2 (Product): Gasoline-91 <br /> ❑ In-Tank Gauging Probe Model: ❑ In-Tank Gauging Probe Model: <br /> ■ Annular Space or Vault Sensor Model: 0794390-420 ■ Annular Space or Vault Sensor Model: 0794390-420 <br /> ■ Piping Sump/Trench Sensor(s) Model: 0794380-208 ■ Piping Sump/Trench Sensor(s) Model: 0794380-208 <br /> ❑ Fill Sump Sensor(s) Model: ❑ Fill Sump Sensor(s) Model: <br /> ❑ Mechanical Line Leak Detector Model: ❑ Mechanical Line Leak Detector Model: <br /> ❑ Electronic Line Leak Detector Model: ❑ Electronic Line Leak Detector Model: <br /> ❑ Tank Overfill/High-Level Sensor Model: ❑ Tank Overfill/High-Level Sensor Model: <br /> ❑ Other (specify equipment in Section E) Model: ❑ Other (specify equipment in Section E) Model: <br /> Tank#3 (Product): Tank#4 (Product): <br /> ❑ In-Tank Gauging Probe Model: ❑ In-Tank Gauging Probe Model: <br /> ❑ Annular Space or Vault Sensor Model: ❑ Annular Space or Vault Sensor Model: <br /> ❑ Piping Sump/Trench Sensor(s) Model: ❑ Piping Sump/Trench Sensor(s) Model: <br /> ❑ Fill Sump Sensor(s) Model: ❑ Fill Sump Sensor(s) Model: <br /> ❑ Mechanical Line Leak Detector Model: ❑ Mechanical Line Leak Detector Model: <br /> ❑ Electronic Line Leak Detector Model: ❑ Electronic Line Leak Detector Model: <br /> ❑ Tank Overfill/High-Level Sensor Model: ❑ Tank Overfill/High-Level Sensor Model: <br /> ❑ Other (specify equipment in Section E) Model: ❑ Other (specify equipment in Section E) Model: <br /> 132: DISPENSE RS/UDC's <br /> Dispenser#: 1-2 Dispenser#: 3-4 <br /> N Dispenser Containment Sensor(s) Model: 0794380-208 ■ Dispenser Containment Sensor(s) Model: 0794380-208 <br /> ■ Shear Valves ■ Shear Valves <br /> ❑ Dispenser Containment Float(s)and Chain(s) ❑ Dispenser Containment Float(s)and Chain(s) <br /> Dispenser#: Dispenser#: <br /> ❑ Dispenser Containment Sensor(s) Model: ❑ Dispenser Containment Sensor(s) Model: <br /> ❑ Shear Valves ❑ Shear Valves <br /> ❑ Dispenser Containment Float(s)and Chain(s) ❑ Dispenser Containment Float(s)and Chain(s) <br /> Dispenser#: Dispenser#: <br /> ❑ Dispenser Containment Sensor(s) Model: ❑ Dispenser Containment Sensor(s) Model: <br /> ❑ Shear Valves ❑ Shear Valves <br /> ❑ Dispenser Containment Float(s)and Chain(s) ❑ Dispenser Containment Float(s)and Chain(s) <br /> C. CERTIFICATION I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers'guidelines. <br /> Attached to this Certification is information(e.g.manufacturers'checklists)necessary to verify that this information is correct and a Plot Plan showing the <br /> layout of monitoring equipment. For any equipment capable of generating such reports,I have also attached a copy of the report; (check all that apply): <br /> ■ System set-up ■ Alarm History Report <br /> �Q�1 WALTON ---- <br /> Signature: ` ('`)"' - ENGINEERING,INC.. <br /> Technician/Cert#: Jessie Wadkins/835391 5307886-UT Date: January IS, 2009 <br /> ©2006 Walton Engineering,Inc. <br />
The URL can be used to link to this page
Your browser does not support the video tag.