Laserfiche WebLink
OUTPUT RELAY SETUP <br />— — — — — — — -- — — — — <br />IN—TANK SETUP <br />R I :RUL <br />— — — — — — — -- — — — — <br />TYPE: <br />STANDARD <br />T I:RUL <br />NORMALLY CLOSED <br />PRODUCT CODE I <br />THERMAL COEFF :.000700 <br />TANK #: I <br />TANK DIAMETER 96.00 <br />TANK PROFILE I PT <br />FULL VOL 10028 <br />IN—TANK ALARMS <br />METER DATA YES <br />ALL:LEAY ALARM <br />END FACTOR: NONE <br />T I:HIGH WATER ALARM <br />CAL UPDATE: NEVER <br />T I:LOW PRODUCT ALARM <br />LEAK TEST METHOD <br />T I:PERIODIC TEST FAIL <br />FLOAT SIZE: 4.0 IN. <br />TEST ON DATE ALL TANK <br />LIQUID SENSOR ALMS <br />FEB 6, 2007 <br />L I:FUEL ALARM <br />WATER WARNING 1.0 <br />START TIME : DISABLED <br />L 5:,FUEL ALARM <br />HIGH WATER LIMIT: 1.5 <br />TEST RATE :0.20 GAL/HR <br />L 6:FUEL ALARM <br />DURATION 2 HOURS <br />L I:SENSOR OUT ALARM <br />MAX OR LABEL VOL: 10028 <br />L 5:SENSOR OUT ALARM <br />OVERFILL LIMIT 85yo <br />TST EARLY,STOP:DISABLED <br />L 6:SENSOR OUT ALARM <br />8523 <br />L I:SHORT ALARM <br />HIGH PRODUCT 90% <br />LEAK TEST REPORT FORMAT <br />L 5:SHORT ALARM <br />9025 <br />ENHANCED <br />L 6:SH0RT ALARM <br />DELIVERY LIMIT 101% <br />1002 <br />ISD SITE ALARMS <br />ISD GROSS PRES FAIL <br />LOW PRODUCT 930 <br />ISD DEGRD PRES FAIL <br />LEAK ALARM LIMIT: 50 <br />ISD VAPOR LEAK FAIL <br />SUDDEN LOSS LIMIT: 50 <br />TANK TILT 0.00 <br />ISD HOSE ALARMS <br />PROBE OFFSET 0.00 <br />ALL;GROSS COLLECT FAIL <br />ALL:DEGRD COLLECT FAIL <br />ALL:FLOW COLLECT FAIL <br />SIPHON MANIFOLDED TANKS <br />T#: NONE <br />LIQUID SENSOR SETUP <br />R 2:PUL <br />LINE MANIFOLDED TANKS <br />— — — — — — — — — — — — <br />TYPE: <br />T#: NONE <br />STANDARD <br />L I:RUL STP SUMP <br />NORMALLY CLOSED <br />TRI—STATE (SINGLE FLOAT) <br />LEAK MIN PERIODIC: 50% <br />CATEGORY : STP SUMP <br />TANK #: 2 <br />5014 <br />LEAK MIN ANNUAL 50% <br />L 2:PUL STP SUMP <br />IN—TANK ALARMS <br />5014 <br />TRI—STATE (SINGLE FLOAT) <br />ALL:LEAK ALARM <br />CATEGORY : STP SUMP <br />T 2:HIGH WATER ALARM <br />T 2:LOW PRODUCT ALARM <br />PERIODIC TEST TYPE <br />T 2:PERIODIC TEST FAIL <br />STANDARD <br />L 3:RUL ANN <br />TRI—STAT5 (SINGLE FLOAT) <br />LIQUID SENSOR ALMS <br />ANNUAL TEST FAIL <br />CATEGORY : ANNULAR SPACE <br />L 2:FUEL ALARM <br />ALARM DISABLED <br />L 5:FUEL ALARM <br />L 6:FUEL ALARM <br />PERIODIC TEST FAIL <br />L 2:SENS0R OUT ALARM <br />ALARM DISABLED <br />L 4:PUL ANN <br />L 5:SENSOR OUT ALARM <br />TRI—STATE (S I NGLE FLOAT) <br />L 6:SENSOR OUT ALARM <br />GROSS TEST FAIL <br />CATEGORY : ANNULAR SPACE <br />L 2:SHORT ALARM <br />ALARM DISABLED <br />L 5:SHORT ALARM <br />L 6:SHORT ALARM <br />ANN TEST AVERAGING: OFF <br />PER TEST AVERAGING: OFF <br />L 5:DISP 1-2 <br />ISD SITE ALARMS <br />TRI—STATE (SINGLE FLOAT) <br />ISD GROSS PRES FAIL <br />TANK TEST NOTIFY: OFF <br />CATEGORY : DISPENSER PAN <br />ISD DEGRD PRES FAIL <br />ISD VAPOR LEAK FAIL <br />TNK TST SIPHON BREAKOFF <br />ISD HOSE ALARMS <br />DELIVERY DELAY 5 MIN <br />L 6:DISP 3-4 <br />ALL:GROSS COLLECT FAIL <br />STICK OFFSET 0.00 <br />TRI—STATE (SINGLE FLOAT) <br />ALL:DEGRD COLLECT FAIL <br />PUMP THRESHOLD 10.00% <br />CATEGORY : DISPENSER PAN <br />ALL:FLOW COLLECT FAIL <br />