My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
D
>
DA VINCI
>
4627
>
2300 - Underground Storage Tank Program
>
PR0231074
>
COMPLIANCE INFO_2013-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/1/2023 11:27:36 AM
Creation date
6/23/2020 6:41:03 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2018
RECORD_ID
PR0231074
PE
2361
FACILITY_ID
FA0002541
FACILITY_NAME
7-ELEVEN INC #20632
STREET_NUMBER
4627
STREET_NAME
DA VINCI
STREET_TYPE
DR
City
STOCKTON
Zip
95207
APN
11002003
CURRENT_STATUS
01
SITE_LOCATION
4627 DA VINCI DR
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231074_4627 DA VINCI_2013-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
431
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PRODUCT <br />PIPING SUMP TESTING <br />Test Method By: O Manufacturer • Industry Standard o Professional Engr o Other (see below) <br />Test Method Uses: o Pressure o Vacuum • Hydrostatic o Other (see below) <br />Measuring Equipment Used: INCON TS -STS (Electronic Sump Test System) <br />Description Tank #1 Tank #2 <br />Tank product <br />Sump material <br />Sump diameter (inches) <br />Sump depth (inches) <br />Height from tank top to highest <br />piping penetration (inches) <br />Height from tank top to lowest <br />electrical penetration (inches) <br />Method of sump attachment to tank <br />Condition of sump prior to testing <br />Port <br />ion of sump tested <br />Is system programmed for fail-safe operation? <br />Was fail-safe verified to be operational? <br />Was sensor removed for testing? <br />Was sensor properly replaced after testing? <br />Depth of water level from tank top (inches) <br />Wait time for water level to stabilize (hr:min) <br />Test start time <br />Initial Probe Reading <br />Test end time <br />Final Probe Reading <br />Test duration (hr:min) <br />Change in water level (t 0.0000 inches) #VALUE! <br />Pass/Fail threshold (10.002 inches/ '41-1r.) 0.0020 <br />TEST RESULT <br />Comments: <br />0 2017 Walton Engineering, Inc. <br />