Laserfiche WebLink
RECEive) <br />I's <br />MAR <br />Appendix VI 13 2017 <br />MONITORING SYSTEM CERTIFICATION <br />For Use By All Jurisdictions Within the State of California �+�v rDNWAH " <br />Authority Cited: Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code o I s" F <br />This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be prepared for <br />each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank system <br />owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br />A. General Information <br />Facility Name: EL DORADO FOOD MART - SHELL Bldg. No.: <br />Site Address: 2320 NORTH EL DORADO BLVD City: STOCKTON Zip: 95204 <br />Facility Contact Person: BOB Contact Phone No.: (209) 994-4400 <br />Make/Model of Monitoring System: VEEDER ROOT TLS 350 Date of Testing/Servicing: 2/21/2017 <br />B. Inventory of Equipment Tested/Certified <br />Check the appropriate boxes to indicate specific equipment inspected/serviced: <br />Tank ID: 87 <br />Tank ID: 91 <br />® In -Tank Gauging Probe. <br />Model: MAG 1 <br />® In -Tank Gauging Probe. Model: MAG 1 <br />® Annular Space or Vault Sensor. <br />Model: <br />302 <br />® Annular Space or Vault Sensor. <br />Model: 302 <br />® Piping Sump / Trench Sensor(s). <br />Model: <br />352 <br />® Piping Sump / Trench Sensor(s). <br />Model: 352 <br />❑ Fill Sump Sensor(s). <br />Model: <br />❑ Fill Sump Sensor(s). <br />Model: <br />❑ Mechanical Line Leak Detector. <br />Model: <br />❑ Mechanical Line Leak Detector. <br />Model: <br />® Electronic Line Leak Detector. <br />Model: <br />PLLD <br />® Electronic Line Leak Detector. <br />Model: PLLD <br />® Tank Overfill / High -Level Sensor. <br />Model: <br />FLAPPER <br />® Tank Overfill / High -Level Sensor. <br />Model: FLAPPER <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />Tank ID: DIE <br />Tank ID: NA <br />® In -Tank Gauging Probe. <br />Model: <br />MAG 1 <br />❑ In -Tank Gauging Probe. <br />Model: <br />® Annular Space or Vault Sensor. <br />Model: <br />302 <br />❑ Annular Space or Vault Sensor. <br />Model: <br />® Piping Sump / Trench Sensor(s). <br />Model: <br />352 <br />❑ Piping Sump / Trench Sensor(s). <br />Model: <br />❑ Fill Sump Sensor(s). <br />Model: <br />❑ Fill Sump Sensor(s). <br />Model: <br />❑ Mechanical Line Leak Detector. <br />Model: <br />❑ Mechanical Line Leak Detector. <br />Model: <br />® Electronic Line Leak Detector. <br />Model: <br />PLLD <br />❑ Electronic Line Leak Detector. <br />Model: <br />® Tank Overfill / High -Level Sensor. <br />Model: <br />FLAPPER <br />❑ Tank Overfill / High -Level Sensor. <br />Model: <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />Dispenser ID: 1-2 <br />Dispenser ID: 3-4 <br />❑ Dispenser Containment Sensor(s). <br />Model: <br />❑ Dispenser Containment Sensor(s). <br />Model: <br />® Shear Valve(s). <br />® Shear Valve(s). <br />® Dispenser Containment Float(s) and <br />Chain(s). <br />® Dispenser Containment Float(s) and <br />Chain(s). <br />Dispenser ID: 5-6 <br />Dispenser ID: 7-8 <br />❑ Dispenser Containment Sensor(s). <br />Model: <br />❑ Dispenser Containment Sensor(s). <br />Model: <br />® Shear Valve(s). <br />® Shear Valve(s). <br />® Dispenser Containment Float(s) and <br />Chain(s). <br />® Dispenser Containment Float(s) and <br />Chain(s). <br />Dispenser ID: <br />ID: <br />[Dispenser <br />❑ Dispenser Containment <br />El Dispenser Containment Sensor(s). <br />Model: <br />Sensor(s). <br />Model: <br />❑ Shear Valve(s). <br />❑ Shear Valve(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />*If the facility contains more tanks or dispensers, copy this form. Include information for every tank and dispenser at the facility. <br />C. Certification -1 certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br />guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information is correct <br />and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports, I have also attached a <br />copy of the report; (check all that apply): ® System set-up ® Alarm history report <br />Technician Name (print): FELIX RAMIREZ Signature: <br />J <br />Certification No.: B34976 License No: 5273934 -UT 08-1740 OTTL <br />Testing Company Name: AFFORDA-TEST Phone No. (209) 744-0113 <br />Testing Company Address: 416 2nd STREET GALT, CA 95632 Date of Testing/Servicing: 02-21-17 <br />Monitoring System Certification Page 1 of 4 2/21/07 <br />