COMPLIANCE INFO_1998-2008
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
E
>
EL DORADO
>
1901
>
2300 - Underground Storage Tank Program
>
PR0231092
>
COMPLIANCE INFO_1998-2008
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/6/2024 2:53:38 PM
Creation date
6/23/2020 6:41:42 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1998-2008
RECORD_ID
PR0231092
PE
2361
FACILITY_ID
FA0001946
FACILITY_NAME
El Dorado Food Mart
STREET_NUMBER
1901
Direction
S
STREET_NAME
EL DORADO
STREET_TYPE
ST
City
STOCKTON
Zip
95206
APN
16508019
CURRENT_STATUS
01
SITE_LOCATION
1901 S EL DORADO ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231092_1901 S EL DORADO_1998-2008.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
488
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
r= LD <br />MONfrWNG SYSTEM CE TIF T <br />ON <br />9/1 State ofCalJvrnicr <br />ocdAuthority Citecl.Chapter67, HJtX n e <br />Chapt rnision 3, Title 23, California Code of Regulations <br />This form must be used to document��'(�"t r ' A� C" <br />mo t i' g equipment. A separate certification or report must be <br />prepared for each monitoring system contrcf `i�'riel; b%,e ft 'an who performs the work. A copy of this form must be provided to <br />the tank system owner/operator. The owner/operator must submit a copyP'of this form to the local agency regulating UST systems <br />within 30 clays of test date. <br />A. General Informatione�Nv <br />A/ ' <br />Facility Name: G — � v,r P <br />Site Address: - <br />Bldg. No.:_ <br />/9Dj �L �p • Zjp 5-t City: ®�-7-®6-1- <br />Zip: C? 2.,:=,(,p <br />Facility Contact Person: Contact Phone No.: ( Zj=fj46— 2.6(47 <br />Make/Model of Monitoring Syster EF Q— TI2 LS -3cx-�' <br />Date of Testing/Servicing: <br />B. Inventory of Equipment Tested/Certified <br />Check the appropriate boxes to indicate snerifir -.i.—# -----._ <br />n -Tank Gauging Probe. Model. <br />nnular Space or Vault Sensor. Model: Zp <br />Piping Sump / Trench Sensor(s). Model: <br />r''�Mechanical <br />Fill Sump Sensor(s). Model: <br />LJ <br />Line Leak Detector. Model: 5? . MLD <br />❑ Electronic Line Leak Detector. Model: <br />❑ Tank Overfill / High -Level Sensor. Model: <br />❑ Other (spec a ui ment !Xpe and model in Section E on Pa a 2). <br />Tank ID: --f 4! <br />A in -Tank Gauging Probe. Model: <br />❑ 9nnular Space or Vault Sensor. Model: <br />Piping Sump / Trench Sensor(s). Model: <br />❑ Fil) Sump Sensor(s). Model: <br />echanical Line Leak Detector. Model: 4.719- r-( t -t> <br />❑ Electronic Line Leak Detector. Model: <br />❑ Tank Overfill / High -Level Sensor. Model: <br />❑ Other (s eci a ui ment !lee and model in Section E on PaLe 2). <br />Dols enser ID: (�6— 2 <br />�ispenser Containment Sensor(s). Model: '2198 <br />.i� Shear Valve(s). <br />❑ Dis enser Containment Float(s) and Chains) <br />Tank ID: <br />❑ In -Tank Gauging Probe. <br />❑ Annular Space or Vault Sensor. <br />Model: <br />❑ Piping Sump / Trench Sensor(s). <br />Model: <br />Model: <br />❑ Fill Sump Sensor(s). <br />Model: <br />❑ Mechanical Line Leak Detector. <br />Model: <br />❑ Electronic Line Leak Detector. <br />Model: <br />17 Tank Overfill / High -Level Sensor. <br />Model: <br />❑ Other (specify equipment type and model in Section E on Pa a 2) <br />Tank ID: <br />❑ In -Tank Gauging Probe. <br />❑ Annular Space or Vault Sensor. <br />Model: <br />Model: <br />❑ Piping Sump / Trench Sensor(s). <br />Model: <br />❑ Fill Sump Sensor(s). <br />Model: <br />❑ Mechanical Line Leak Detector. <br />Model: <br />❑ Electronic Line Leak Detector. <br />Model: <br />❑ Tank Overfill / High -Level Sensor. <br />Model: <br />❑ Other (specify equipment type and model in Sectinn <br />Dispenser ID: <br />❑ Dispenser Containment Sensoils). Model: <br />❑ Shear Valve(s). <br />❑ Dis enser Containment Float(s) and Chain(s). <br />Dis enser ID: 3 �r Dispenser ID: <br />spenser Containment Sensor(s). Model:LJDispenser Containment Sensor(s). Model:Shear Valve(s). ❑ Shear Valve(s). <br />❑ <br />2L= Containment Float(s) and Chain(s). ❑s e <br />Dinser Containment Float(s) and Chain(s). <br />Dispenser ID: Dispenser ID: <br />❑ Dispenser Containment Sensor(s). Model: ❑ Dispenser Containment Sensor(s). Model: <br />❑ Shear Valve(s). ❑ Shear Valve(s). <br />❑Dis enser Containment Float(s) and Chain(s). ❑Dis enser Containment Floats) and Chain(s). <br />*If the facility contains more tanks or dispensers, copy this form. Include information for every tank and dispenser at the facility. <br />C. Certification - I certify that the equipment identified in this document was inspected/serviced in accordance with the <br />manufacturers' guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this <br />information is correct and a Plot Plan showing the layout of monitoring equ'p eat. For any equiDment capable of generating such <br />reports, I have also attached a copy c the report; (check n/l that app/6): Syste set -u Alarm history report <br />Technician Name (print): ( N iib Signature: <br />Certification No.: License. No.: _(� <br />Testing Company Name: 7-E��"T Phone No.:( 2®�; ?° — C' t ! 2 <br />Site Address: P701 S. E fr ® �U �3-r Date of Testing/Servicing: -3124107- <br />Page 1 of 3 <br />Monitoring System Certification <br />D. Results of Testing/Servicing <br />03/)1 <br />