My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2009-2012
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
E
>
EL DORADO
>
1901
>
2300 - Underground Storage Tank Program
>
PR0231092
>
COMPLIANCE INFO_2009-2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/6/2024 3:01:37 PM
Creation date
6/23/2020 6:41:43 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009-2012
RECORD_ID
PR0231092
PE
2361
FACILITY_ID
FA0001946
FACILITY_NAME
El Dorado Food Mart
STREET_NUMBER
1901
Direction
S
STREET_NAME
EL DORADO
STREET_TYPE
ST
City
STOCKTON
Zip
95206
APN
16508019
CURRENT_STATUS
01
SITE_LOCATION
1901 S EL DORADO ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231092_1901 S EL DORADO_2009-2012.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
473
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
B <br /> All <br /> (XiLp <br /> l Jan 002 Page <br /> _ ., r, , <br /> c"cle SF, fes. TANK ANNULAR TESTING <br /> Test Method Developed By: 0 Tank Manufacturer ' Industry Standard 0 Professional Engineer <br /> ❑Other(Spec) <br /> Test Method Used: d(f'ressure 0 Vacuum ❑Hydrostatic <br /> ❑Other(Spec) <br /> Test Equipment Used: rig siF t., Equipment Resolution: <br /> Tank# Tank# Tank# Tank# <br /> Is Tank Exempt From Testing?' 0 Yes kNo 0 Yes ❑No 0 Yes ❑No 0 Yes ❑No <br /> Tank Capacity: <br /> Tank Material: 54; e- <br /> Tank Manufacturer: <br /> Product Stored: ' 9/ <br /> Wait time between applying <br /> pressure/vacuum/water and <br /> starting test: <br /> Test Start Time: <br /> Initial Reading(R): 3 /i <br /> Test End Time: <br /> Final Reading(RF): <br /> Test Duration: /f <br /> Change in Reading(RF R) <br /> Pass/Fail Threshold or Criteria: f? "S <br /> Test Result: )(Pass 0 Fail 0 Pass ❑Fail ❑ Pass ❑Fail ❑ Pass ❑Fall <br /> Was sensor removed for testing? W. es 0 No ❑NA ❑Yes O No DNA ❑Yes O No ❑NA O Yes ❑No ❑NA <br /> Was sensor properly replaced and t Yes O No O NA Oyes ❑No O NA ❑Yes O No O NA ❑Yes O No ❑NA <br /> verified functional after testis ? `r1 <br /> ComMentS—(include information on repd'rrs made prior to testing,and recommended follow-up for farted tests) <br /> r Secondary containment systems where the continuous monitoring automatically monitors both the primary and secondary <br /> containment,such as systems that are hydrostatically monitored or under constant vacuum,are exempt from periodic containment <br /> testing. {California Code of Regulations,Title 23,Section 2637(a)(6)) <br />
The URL can be used to link to this page
Your browser does not support the video tag.