My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2002-2005
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
E
>
EL DORADO
>
7906
>
2300 - Underground Storage Tank Program
>
PR0231094
>
COMPLIANCE INFO_2002-2005
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/23/2020 2:10:05 PM
Creation date
6/23/2020 6:42:08 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2002-2005
RECORD_ID
PR0231094
PE
2361
FACILITY_ID
FA0003632
FACILITY_NAME
AJS MINI MART INC
STREET_NUMBER
7906
Direction
N
STREET_NAME
EL DORADO
STREET_TYPE
ST
City
STOCKTON
Zip
95207
APN
07935016
CURRENT_STATUS
01
SITE_LOCATION
7906 N EL DORADO ST
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231094_7906 N EL DORADO_2002-2005.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
298
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
J. ION, <br /> UNIFIED PROCRAM CONSOLIDATED FORM <br /> TANKS <br /> UNDERGROUND ST ORAGE TANKS - TANK PAGE 1 <br /> (Two pages per tank) <br /> Page I of 2 <br /> TYPE OF ACTION ❑ 1.NEW PERMIT ❑ 4.AMENDED PERMIT ® 5.CHANGE OF INFORMATION ❑ &TEMPORARY TANK CLOSURE 430 <br /> (Check one item only) ❑ 3.RENEWAL PERMIT _system modiffication ❑ 7.PERMANENTLY CLOSED ON SITE <br /> (Specify reason) (Specify reason) ❑ 8.TANK REMOVED <br /> 13USINESS NAME(Same as FACILITY NAME or DBA-Doing Business As) 3 1 FACILITY.ID: <br /> ARCO 2130 rh3 <br /> LOCATION WITHIN SITE(Optional) 411 <br /> I.TANK DESCRIPTION <br /> (A scaled plot plan with the location of the UST system including buildings and landmarks shall be submitted to the local agency.) <br /> NK ID#O,�O�/�53 432 TANK MANUFACTURER 433 COMPARTMENTALIZED TANK ❑Yes ® No 434 <br /> - UNLEADED XERXES If"Yes,"complete one page for each compartment <br /> DATE INSTALLED 435 TANK CAPACITY IN GALLONS 436 NUMBER OF COMPARTMENTS <br /> 437 <br /> (YEAR/MO) <br /> 1993/6 10,000 <br /> ADDITIONAL DESCRIPTION(For local use only) 438 <br /> II.TANK CONTENTS <br /> TANK USE 439. PETROLEUM TYPE 440 <br /> S I. MOTOR VEHICLE FUEL ®la. REGULAR UNLEADED ❑2. LEADED ❑5. JET FUEL <br /> (Ifchecked,complete Petroleum Type) ❑ 1b. PREMIUM UNLEADED ❑3. DIESEL ❑6. AVIATION GAS <br /> ❑ 2. NON-FUEL PETROLEUM ❑Ic. MIDGRADE UNLEADED ❑4. GASOHOL ❑99.OTHER: <br /> ❑ 3. CHEMICAL PRODUCT COMMON NAME (from Hazardous Materials Inventory page) 441. CAS#(from Hazardous Materials Inventory page) 442 <br /> ❑ 4. HAZARDOUS WASTE Gasoline 8006-61-9 <br /> (Includes Used Oil) <br /> ❑ 95.UNKNOWN <br /> III.TANK CONSTRUCTION <br /> TYPE OF TANK ❑ 1. SINGLE WALL ❑3. SINGLE WALL WITH EXTERIOR [:15. SINGLE WALL WITH INTERNAL BLADDER SYSTEM 443. <br /> (Check one item only) MEMBRANE LINER ❑95. UNKNOWN <br /> S 2. DOUBLE WALL [14. SINGLE WALL IN A VAULT ❑99. OTHER <br /> TANK MATERIAL-primary tank ❑ 1. BARE STEEL 103. FIBERGLASS/PLASTIC [15. CONCRETE- ❑95.UNKNOWN 444 <br /> (Check one item only) [12. STAINLESS STEEL [14. STEEL CLAD W/FIBERGLASS [IS. FRP COMPATIBLE ❑99.OTHER: <br /> REINFORCED PLASTIC FRP W/100%METHANOL <br /> TANK MATERIAL-secondary tank ❑ 1. BARE STEEL S 3. FIBERGLASS/PLASTIC ❑8. FRP COMPTIBLE W/100%METHANOL ❑95.UNKNOWN 445. <br /> (Check one item only) ❑2. STAINLESS STEEL[14. STEEL CLAD W/FIBERGLASS ❑9. FRP NON-CORRODABLE JACKET ❑99.OTHER <br /> REINFORCED PLASTIC(FRP) ❑ 10. COATED STEEL <br /> ❑5. CONCRETE <br /> TANK INTERIOR LINING ❑ 1.RUBBER LINED ❑3.EPDXY LINING ❑5.GLASS LINING ❑95.UNKNOWN 446. DATE INSTALLED 447 <br /> OR COATING ❑2.ALKYD LINING [14.PHENOLIC LINING S 6.UNLINED ❑99.OTHER <br /> (Check one item only) <br /> OTHER CORROSION ❑1.MANUFACTURED CATHODIC ❑3.FIBERGLASS REINFORCED PLASTIC ❑95.UNKNOWN 448. DATE INSTALLED 449 <br /> PROTECTION PROTECTION ❑4.IMPRESSED CURRENT ❑99.OTHER <br /> If A licable ❑2.SACRIFICIAL ANODE <br /> SPILL AND OVERFILL YEAR INSTALLED 450. TYPE 451. OVERFILL PROTECTION EQUIPMENT: YEAR INSTALLED 452. <br /> (Check all that apply) S 1.SPILL CONTAINMENT 1993 ❑ 1.ALARM S 3.FILL TUBE SHUT OFF VALVE <br /> S 2.DROP TUBE 1993 [12.BALL FLOAT ❑4.EXEMPT <br /> [13.STRIKER PLATE <br /> IV.TANK LEAK DETECTION <br /> (A description of the monitoring program shall be submitted to the local agency.) <br /> IF SINGLE WALL TANK 453 IF DOUBLE WALL TANK OR TANK WITH BLADDER 454, <br /> (Check all that apply) (Check one item only) <br /> ❑ 1. VISUAL(EXPOSED PORTION ONLY) ❑5.MANUAL TANK GAUGING(MTG) ❑1.VISUAL(SINGLE WALL IN VAULT ONLY) <br /> ❑2. AUTOMATIC TANK GAUGING(ATG) ❑6.VADOSE ZONE S 2.CONTINUOUS INTERSTITIAL MONITORING <br /> ❑3.CONTINUOUS ATG ❑7.GROUNDWATER ❑3.MANUAL MONITORING <br /> ❑4. STATISTICAL INVENTORY RECONCILIATION ❑S.TANK TESTING <br /> (SIR)+BIENNIAL TANK TESTING ❑99.OTHER <br /> V.TANK CLOSURE INFORMATION/ PERMANENT CLOSURE IN PLACE <br /> ESTIMATED DATE LAST USED(YR/MO/DAY) 455 ESTIMATED QUANTITY OF SUBSTANCE REMAINING 456. TANK FILLED WITH INERT MATERIAL? 457 <br /> gallons ❑Yes ❑ No <br /> UPCF hwf vre-b(1/99)-1/4 http://www.unidocs.org Rev.02/16/00 <br />
The URL can be used to link to this page
Your browser does not support the video tag.