My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2008-2009
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
E
>
EL DORADO
>
7906
>
2300 - Underground Storage Tank Program
>
PR0231094
>
COMPLIANCE INFO_2008-2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/10/2023 1:39:29 PM
Creation date
6/23/2020 6:42:20 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2008-2009
RECORD_ID
PR0231094
PE
2361
FACILITY_ID
FA0003632
FACILITY_NAME
AJS MINI MART INC
STREET_NUMBER
7906
Direction
N
STREET_NAME
EL DORADO
STREET_TYPE
ST
City
STOCKTON
Zip
95207
APN
07935016
CURRENT_STATUS
01
SITE_LOCATION
7906 N EL DORADO ST
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231094_7906 N EL DORADO_2008-2009.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
421
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Alarms <br />HIGH CURRENT <br />High current has been detected. The motor rotor could be locked. One or more of the phases going to the motor <br />could be open. Check the motor by checking the resistance between the terminals (see Table 8 on page 24). <br />Check all the wiring going to the motor for opens and shorts. <br />OVER VOLTAGE <br />High input voltage has been detected. Check the input voltage to make sure that it is within specifications (see <br />Table 6 on page 23). <br />LOW VOLTAGE <br />Low input voltage has been detected. Check the input voltage to make sure that it is within specifications (see <br />Table 6 on page 23). <br />OVER TEMPERATURE <br />High internal drive temperature has been detected. Check to make sure that the drive has the proper clearance on <br />all sides and that nothing is obstruction the airflow. Check to make sure that the fan is running. <br />PRESSURE SENSOR FAULT <br />Pressure transducer has faulted. Check to make sure that the pressure transducer is connected. Check the wiring <br />to the transducer. <br />SELF -TEST FAULT <br />Software has detected errors in the drive. Turn off power, check all setup switches and wiring then apply power to <br />the drive. <br />MOTOR DRIVE FAULT <br />Drive has detected a problem running the motor. Check all drive wiring (see Table 6 on page 23, Table 7 on <br />page 23, and Table 8 on page 24). <br />COMMUNICATIONS FAULT <br />Drive has detected communication errors. In standalone configuration check cable connected to J9 (see Figure 4 <br />on page 8). In multi -unit configuration, check the Slave COM connections and wiring (Figure 15 on page 25) in <br />each drive. <br />B-1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.