Laserfiche WebLink
ONIT NG SYSTEM CERTIFIC ION <br />e By All Jurisdictions Within the State of California <br />Authority Cited: Chapter 6.7, He and Safety Code; Chapter 16, Division 3 Title 23, Cab nia Code of Regulations <br />This form must be used to document testing and servicing of monitoring equipment. If more than one monitoring system control panel is installed at the facility, a separate <br />certification or report must be prepared for each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank <br />system owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br />A. General Information <br />Facility Name: ARCO #02130, CC18022643 City: STOCKTON CA Zip: 95204 <br />Site Address: 7906 N. EL DORADO @ HAMMER Contact Phone No: 957-2987 <br />Date of Testing/Service: 07/24/2009 <br />Facility Contact Person: DEALER/MANAGER <br />Make/Model of Monitoring System:V.R. TLS -350 R Work Order Number: 2267978 <br />B. Inventory of Equipment Tested/Certified <br />Check the appropriate boxes to indicate specific equipment inspected/serviced <br />Tank ID: 1-87#1 <br />Tank ID: 2-87#2 <br />X In -Tank Gauging Probe. <br />Model: MAG <br />ZI In -Tank Gauging Probe. <br />Model: MAG <br />X Annular Space or Vault Sensor. <br />Model: 407 <br />21 Annular Space or Vault Sensor. <br />Model: 407 <br />X Piping Sump/Trench Sensor(s). <br />Model: 323 <br />7X Piping Sump/Trench Sensor(s). <br />Model: 323 <br />X Fill Sump Sensor($). <br />Model: 323 <br />Fill Sump Sensor(s). <br />Model: 323 <br />Mechanical Line Leak Detector. <br />Model: <br />Mechanical Line Leak Detector. <br />Model: <br />X Electronic Line Leak Detector. <br />Model: RED JACKET (CPT) <br />Electronic Line Leak Detector. <br />Model: <br />Tank Overfill/High-Level Sensor. <br />Model: <br />Tank Overfill/High-Level Sensor. <br />Model: <br />Other (specify equipment type and <br />model in Section E on page 2). <br />Other (specify equipment type and model in Section E on page 2). <br />Tank ID: <br />Tank ID: <br />79 In -Tank Gauging Probe. <br />Model: MAG <br />In -Tank Gauging Probe. <br />Model: MAG <br />X Annular Space or Vault Sensor. <br />Model: 407 <br />Annular Space or Vault Sensor. <br />Model: 407 <br />X Piping Sump/Trench Sensor(s). <br />Model: 323 <br />_71 Piping Sump/Trench Sensor(s). <br />Model: 323 <br />X Fill Sump Sensor(s). <br />Model: 323 <br />X Fill Sump Sensor(s). <br />Model: 323 <br />Mechanical Line Leak Detector. <br />Model: <br />Mechanical Line Leak Detector. <br />Model: <br />Electronic Line Leak Detector. <br />Model: <br />X Electronic Line Leak Detector. <br />Model: RED JACKET (CPT) <br />Tank Overfill/High-Level Sensor. <br />Model: <br />Tank Overfill/High-Level Sensor. <br />Model: <br />Other (specify equipment type and model in Section E on page 2). <br />Other (specify equipment type and model in Section E on page 2). <br />Dispenser : 1/2 <br />Dispenser ID: 3/4 <br />® Dispenser Containment Sensor(s) <br />Model: 323 <br />X Dispenser Containment Sensor(s) <br />Model: 323 <br />XD Shear Valve(s). <br />X Shear Valve(s) <br />❑ Dispenser Containment Float(s) and Chain(s). <br />7 Dispenser Containment Float(s) and Chain(s). <br />Dispenser ID: 5/6 <br />Dispenser ID: 7/8 <br />X❑ Dispenser Containment Sensor(s) <br />Model: 323 <br />X Dispenser Containment Sensor(s). <br />Model: 323 <br />XO Shear Valve(s). <br />Shear Valve(s). <br />171 Dispenser Containment Float(s) and Chain(s). <br />Dispenser Containment Float(s) and Chain(s). <br />Dispenser ID: <br />Dispenser ID: <br />❑ Dispenser Containment Sensor(s) <br />Model: <br />Dispenser Containment Sensor(s). <br />Model: <br />❑ Shear Valve(s). <br />El Shear Valve(s). <br />ID Dispenser Containment Float(s) and Chain(s). <br />El Dispenser Containment Float(s) and Chain(s). <br />" If the facility contains more tanks or dispensers, copy this form. Include information for every tank and dispenser at the facility. <br />C. Certification <br />I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' guidelines. <br />Attached to this certification is information (e.g manufacturers' checklists) necessary to verify that this information is correct. <br />and a Site Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports, I have also attached <br />a copy of the (Check all that apply): ❑ System set-up X❑ Alarm history report <br />Technician Name (print): JOEY MESA Signature: L% 1�— <br />Certification No.: A27796 License. NO.: 743160_(Class'A' General Enginering Contractor License) <br />Testing Company Name:Tanknology Phone No.: (80 0) 800-4633 <br />Site Address: 8501 N. MoPac Expressway, suite 400, Austin, TX 78759 Date of Testing/Servicing: 07/24/2009 <br />Monitoring System Certification Page 1 of 3 Based on CA form dated 03/01 <br />