Laserfiche WebLink
San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California95205-6232 <br /> Telephone., (209) 468-3420 Fax. (209) 468-3433 Web:wWW.sjgov.oW/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date- <br /> N <br /> AJ [DK'.'1'R/",,['10 (..','T "'I'OCKTON 21, 20'1`3 <br /> M I N! R fP" <br /> UST System Observations <br /> 321 CCR 2636(c)(1) All releases in secondary piping do not flow to a collection sump c V o R o COS <br /> 322 CCR 2636(f)(2) Line leak detector not installed o V o R D COS <br /> 323 CCR 2636(f)(2) Leak detector failed to detect a 3.0 gph leak at 10 psi Ei V ii R o COS <br /> 324 CCR 2635(b) No spill bucket installed or failed to provide a means to keep it empty u V Ei R o COS <br /> 325 CCR 2635(b) Spill container failed to contain a minimum capacity of five gallons o V o R E3 COS <br /> 326 CCR 2635(b)(2) Overfill prevention system not present or failed to meet overfill requirements o V o R D COS <br /> 327 CCR 2635(b)(2) Overfill prevention was overridden o V o R o COS <br /> 328 HSC 25283.5 Unburied below grade LIST failed to meet exemption status o V o R o COS <br /> 329 CCR 2717.1(g) Tampered with red tag o V Ei R Ei COS <br /> 330 CCR 2717.1(f) Deposited petroleum into a red tagged LIST o V o R o COS <br /> 331 HSC 25299(Q(2) Tampered with or disabled leak detection devices or alarms o V o R o COS <br /> 332 CCR 2631.1 LIST system not compatible with the substance stored Ei V o R Ei COS <br /> 333 HSC 25298(b) Failed to comply with temporary closure requirements o V o R o COS <br /> 334 HSC 25298(c) Failed to comply with permanent closure requirements El V OR o COS <br /> Non-Pressurized Piping <br /> 401 CCR 2636(a)(3) Suction piping not properly sloped or incorrectly located check valve o V o R o COS <br /> 402 CCR 2643(4) Daily monitoring of suction pipe(pre-Jan 1984)not performed o V Ei R c COS <br /> 403 CCR 2643(d) Triennial 0.1 gph line test for conventional suction piping not performed(pre-January 1984) o V Ei R Ei COS <br /> 404 CCR 2643(e) Biennial 0.1 gph test for gravity piping not performed(pre-January 1984) o V o R o COS <br /> Other Violations <br /> 2010 See below Unlisted Administration/Documentation violation Ei V c R D COS <br /> 2030 See below Unlisted Operations/Maintenance violation o V o R Ei COS <br /> 2060 See below Unlisted Design/Construction violation ❑V Ej R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS 1,CLASS 11,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 106 CCR 2632 Monitoring and response plans not current or approved by the EHD. <br /> T,'i.I i� <br /> 0,- �s riol curfend �r rvl$' approved by fie 'E-HD, In;r,33 Monitoring p!ari n I D 0 5 0 4 1 <br /> Hlhe Foil,(jw;H,'�,g,, Me."ho' the, Serr,,,�or <br /> (8,-7 Mastes, STP Sulnij "Pi'e'e m0iiitoring P'e�-fon'-'­'d <br /> Modlei is li, te�,.! as a '71,,i4380-323, "�.his is i�'Icorred,.. 'Che correlct lleaik Senq w is a 208, ;,e nr a0nix­;,", must <br /> iog <br /> be liploaded to flh,,,', R'sPcilting SysJe�-n,(CERS). kiinnei,Ha tely <br /> nec,.�.,ssary auz'dl it f".r i­eviewbythe ErHE"), <br /> V <br /> MiS ( <br /> -le 1 <br /> a4 � flp,'jo�' <br /> Page 3 of 5 <br />