My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1986-1999
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
F
>
FREMONT
>
2285
>
2300 - Underground Storage Tank Program
>
PR0231111
>
COMPLIANCE INFO_1986-1999
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/12/2023 8:38:01 AM
Creation date
6/23/2020 6:42:57 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1986-1999
RECORD_ID
PR0231111
PE
2361
FACILITY_ID
FA0001659
FACILITY_NAME
QUIK STOP MARKET #7039
STREET_NUMBER
2285
Direction
E
STREET_NAME
FREMONT
STREET_TYPE
ST
City
STOCKTON
Zip
95205
APN
141-214-03
CURRENT_STATUS
01
SITE_LOCATION
2285 E FREMONT ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231111_2285 E FREMONT_1986-1999.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
461
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
In <br />:.r <br />► Highly accurate Magne- <br />tostrictive measurement <br />technology <br />► past, accurate leak tests <br />► MAG 1(0.1 GPH) and <br />MAG 2(0.2 GPH) probes <br />available <br />Series 8473 MAG 2 Probe <br />The MAG 2 probe provides the same reliable inventory <br />control features and fluid compatibility as the MAG 1 <br />probe, but offers 0.2 GPH leak detection at a lower cost. <br />It offers MAG probe performance with 0.2 GPH monthly <br />monitoring capability. <br />► MAG 1 probe third party The MAG 2 probe has also been third -party tested <br />certified to exceed U.S. and certified to exceed U.S. E.P.A. standards for 0.2 <br />E.P.A. performance GP.H automatic tank gauging. See the summary of leak <br />standards for 0.1 GPH test performance on back or call us for a copy of the <br />Volumetric Tank Tight complete test results. <br />ness Testing <br />► Mag 1 probe compatible <br />with TLS -350 and TLS - <br />350R with CSLD for <br />continuous statistical <br />leak detection <br />► MAG 2 probe third -party <br />certified to exceed U.S. <br />E.P.A. performance <br />standards for 0.2 <br />GPH Automatic Tank <br />Gauging <br />► Compatible with, <br />gasolines, diesel and <br />other approved fluids <br />MAG 1 MAG 2 ► Water measurement <br />capability <br />► 2" and 4" Float Kits available <br />Series 8473 MAG 1 Probe <br />The MAG 1 probe provides highly accurate, trouble-free <br />performance in gasolines, diesel and a wide variety of <br />approved fluids. Its r: �agnetostrictive technology and five - <br />point temperature sensing make it capable of extremely <br />accurate inventory control and in -tank leak testing. <br />The MAG 1 probe has been third -party tested and <br />certified to perform far better than the U.S. E.P.A. <br />standards for both 0.1 GPH volumetric tank tightness <br />testing and 0.2 GPH automatic tank gauging. See the <br />summary of leak test performance on back or call us for <br />a copy of the complete test results. <br />MAG 1 Probe and the TLS -350 with CSLD — <br />Leak detection without shutting down your tanks! <br />CSLD, Continuous Statistical Leak Detection, is a new, <br />advanced tank testing technology that makes full use of <br />the TLS -350 and TLS -3508's In -tank monitoring capa- <br />bilities. CSLD eliminates the need for tank shutdown to <br />perform a leak test — no lost business, no lost <br />operating time! <br />The TLS -350 and TLS -3508 equipped with CSLD use <br />the MAG 1 probe to continuously monitor fuel height and <br />temperature information to detect idle times in the tank. <br />During each idle time, data are collected and combined <br />With information from other idle periods to form a highly <br />accurate leak detection database. Sophisticated statisti- <br />cal analysis techniques in CSLD constantly evaluate the <br />database to discard invalid data and perform leak tests <br />based on only high-quality information in the current <br />database. In fact, a new leak test is performed every time <br />new data from an idle period is added. <br />its the next generation in leak detection technology <br />made possible, in part, by the accuracy of the <br />MAG 1 probe! <br />Approved for. Aboveground Tank Applications <br />Veeder-Root Magnetostrictive Probes are approved for <br />use in aboveground storage tanks to monitor fuel inven- <br />tory. An AST Installation Kit (Form Number 312020-984) <br />is required for these applications and is available from <br />Veeder-Root or your authorized Veeder-Root distributor. <br />
The URL can be used to link to this page
Your browser does not support the video tag.