Laserfiche WebLink
71 <br /> �(: � tyouAces <br /> STATE OF CALIFORNIA <br /> STATE WATER RESOURCES CONTROL BOARD 3 g <br /> UNDERGROUND STORAGE TANK PERMIT APPLICATION - FORM B W�' <br /> a <br /> "r <br /> •CSL IROF H�' <br /> COMPLETE A SEPARATE FORM FOR EACH TANK SYSTEM. <br /> MARK ONLY ❑ 1 NEW PERMIT ❑ 3 RENEWAL PERMIT ❑ 5 CHANGE OF INFORMATION PERMANENTLY CLOSED <br /> ONE ITEM ❑ 2 INTERIM PERMIT F-14 AMENDED PERMIT ❑ 6 TEMPORARY TANK CLOSURE 8 TANK REMOVED <br /> DBA OR FACILITY NAME WHERE TANK IS INSTALLED: a K. 5to p <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS– SPECIFY IF UNKNOWN <br /> A OWNER'S TANK 1.D.# r V i"1 B. MANUFACTURED BY: G. 1 'jQ <br /> C. DATE INSTALLED(MO/DAYNEAR) { D. TANK CAPACITY IN GALLONS: <br /> II.TANK CONTENTS IF A-1 IS MARKED,COMPLETE ITEM C. <br /> r A 1 MOTOR VEHICLE FUEL ❑ 4 OIL B. C. /d la REGULAR UNLEADED ❑ 3 DIESEL ❑ 6 AVIATION GAS <br /> ❑ 2 PETROLEUM E:] 80 EMPTY 1 PRODUCT El 1b PREMIUM UNLEADED ❑ 4 GASAHOL ❑ 7 METHANOL <br /> ❑ lc MIDGRADE UNLEADED ❑ 5 JET FUEL ❑ 8 M85 <br /> ❑ 3 CHEMICAL PRODUCT ❑ 95 UNKNOWN ❑ 2 WASTE ❑ 2 LEADED ❑ 99 OTHER(DESCRIBE IN ITEM D.BELOM <br /> D. IF(A.1)IS NOT MARKED, ENTER NAME OF SUBSTANCE STORED C.A.S.#: <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOXES A,B,AND C.AND ALL THAT APPLIES IN BOX D AND E <br /> A. TYPE OF 1 DOUBLE WALL ❑ 3 SINGLE WALL WITH EXTERIOR LINER ❑ 5 INTERNAL BLADDER SYSTEM ❑ 95 UNKNOWN <br /> SYSTEM V2 SINGLE WALL ❑ 4 SINGLE WALL IN A VAULT ❑ 99 OTHER <br /> B. TANK 1 BARE STEEL ❑ 2 STAINLESS STEEL ❑ 3 FIBERGLASS ❑ 4 STEEL CLAD W/FIBERGLASS REINFORCED PLASTIC <br /> MATERIAL ❑ 5 CONCRETE ❑ 6 POLYVINYL CHLORIDE ❑ 7 ALUMINUM ❑ 8 100% METHANOL COMPATIBLE W/FRP <br /> (Primary Tank) ❑ 9 BRONZE ❑ 10 GALVANIZED STEEL ❑ 95 UNKNOWN ❑ 99 OTHER <br /> I <br /> C.INTERIOR ❑ 1 RUBBER LINED ❑ ALKYD LINING ❑ 3 EPDXY LINING ❑ 4 PHENOLIC LINING <br /> LINING OR ❑ 5 GLASS LINING V UNLINED E:]UNLINED F_] 99 OTHER <br /> COATING IS LINING MATERIAL COMPATIBLE WITH 100% METHANOL? YESIc. NO— <br /> D.EXTERIOR ❑ 1 POLYETHYLENE WRAP ❑ 2 COATINGV91 <br /> VINYL WRAP ❑ 4 FIBERGLASS REINFORCED PLASTIC <br /> CORROSION <br /> f PROTECTION ❑ 5 CATHODIC PROTECTION E] 91 NONE UNKNOWN ❑ 99 OTHER 1 01 F2 A <br /> I SPILL CONTAINMENTNSTALLED(YEAR) OVERF,$VPREVENTION EQUIPMENT INSTALLED(YEAR)rl' Ln <br /> r E.SPILL AND OVERFILL,etc. DROP TUBE YES 'i� NO TIER PLATE YES NO DISPENSER CONTAINMENT YES NO <br /> Aff- <br /> IV.PIPING INFORMATION CIRCLE A IF ABOVE GROUND OR U IF UNDERGROUND,BOTH IF APPLICABLE <br /> l <br /> A. SYSTEM TYPE A U 1 SUCTION A4 0 2 PRESSURE A U 3 GRAVITY A U 4 FLEXIBLE PIPING A U 99 OTHER <br /> I B. CONSTRUCTION U ,i1 SINGLE WALL A U 2 DOUBLE WALL A U 3 LINED TRENCH A U 95 UNKNOWN A U 99 OTHER <br /> C. MATERIAL AND A U 1 BARE STEEL A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC)A U 4 FIBERGLASS PIPE <br /> CORROSION A U 5 ALUMINUM A U 6 CONCRETE A U 7 S L W/COATING A U 8 100% METHANOL COMPATIBLE W/FRP <br /> PROTECTION A U ,9 GALVANIZED STEEL A U 10 CATHODIC PROTECTION U 5 UNKNOWN A U 99 OTHER <br /> E D. LEAK DETECTION r" 1 MECHANICAL LINE LEAK t 2 UNE TIGHTNESS 3 CONTINUOUS INTERSTITIAL 4 ELECTRONIC UNE 5 AUTOMATIC PUMP <br /> i <br /> DETECTOR ® TESTING MONITORING LEAK DETECTOR ❑ SHUTDOWN ❑ 99 OTHER <br /> I� V.TANK LEAK DETECTION oe <br />[ ;: ❑ 1 VISUAL CHECK RECONCILIATIONMANUAL ORY ❑ 3 VADOZE MONITORING ❑ 4 AUTOMATGAUGING IC TANK ❑ 5 GROUND MONITORING TER 6 TESTINGTANK <br />` ❑ 7 CONTINUOUS <br /> INTERSTITIAL V SIR ❑ 9 TANEK GAUGING TESTING❑ 10 MONTHLY TANK ❑ 95 UNKNOWN ❑ 99 OTHER <br /> VI.TANK CLOSURE INFORMATION(PERMANENT CLOSURE IN-PLACE) <br />'i <br /> I 1.ESTIMATED DATE LAST USE(D,(MO/DAYNR) 2.ESTIMATED QUANTITY OF 3.WAS TANK FILLED WITH YES ❑ NO <br /> lklCb F";', SUBSTANCE REMAINING GALLONS INERT Mt!l <br /> ATERIAL? <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY F ARJUY4ND TO THE BEST OF MY KNOWLEDGE,IS TRUE AND CORRECT <br /> TANK OWNER'S NAME DAT <br /> (PRINTED b SIGNATURE) {\ n ( � <br /> LOCAL AGENCY USE ONLY THE STATE I.D.NUMBER IOM\POSEDWHE FOUR NUMBERS BELOW <br /> COUNTY# JURISDICTION# FACILITY# TANK# <br /> STATE I.Dl mFTTI 11 1 1 Ill 1011111110111 <br /> PERMIT NUMBER PERMIT APPROVED BY/DATE PERMIT EXPIRATION DATE <br /> THIS FORM MUST BE ACCOMPANIED BY A PERMIT APPLICATION-FORM A,UNLESS A CURRENT FORM A HAS BEEN FILED. FORM C MUST BE COMPLETED FOR INSTALLATIONS. THIS FORM <br /> SHOULD BE ACCOMPANIED BY A PLOT PILE THIS FORM WITH THE LOCAL AGENCY IMPLEMENTING THE U ERGROUND STORAGE TANK REGULATIONS <br /> FORM B (6-95) R <br /> ` c <br />