FA0001659
FACILITY_NAME
QUIK STOP MARKET #7039
STREET_NUMBER
2285
Direction
E
STREET_NAME
FREMONT
STREET_TYPE
ST
City
STOCKTON
Zip
95205
APN
141-214-03
CURRENT_STATUS
01
SITE_LOCATION
2285 E FREMONT ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231111_2285 E FREMONT_1986-1999.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
461
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• • g <br /> puwCt$ <br /> STATE OF CALIFORNIA +����'""• `Oi <br /> STATE WATER RESOURCES CONTROL BOARD <br /> UNDERGROUND STORAGE TANK PERMIT APPLICATION - FORM B <br /> COMPLETE A SEPARATE FORM FOR EACH TANK SYSTEM. <br /> MARK ONLY ❑ 1 NEW PERMIT ❑ 3 RENEWAL PERMIT ❑ 5 CHANGE OF INFORMATION ❑ PERMANENTLY CLOSED ON SITE <br /> ONE ITEM ❑ 2 INTERIM PERMIT ❑ 4 AMENDED PERMIT ❑ 6 TEMPORARY TANK CLOSURE 8 TANK REMOVED <br /> DBA OR FACILITY NAME WHERE TANK IS INSTALLED: Q Y-. 3M 4-- '?F) <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS- SPECIFY IF UNKNOWN <br /> A. OWNER'S TANK 1.D.# ® B. MANUFACTURED BY: V rl�4_f,..5C>jj <br /> C. DATE INSTALLED(MO/DAYNEAR) , 2 D. TANK CAPACITY IN GALLONS: <br /> ITANK CONTENTS IF A•1 IS MARKED,COM— <br /> PLETE ITEM C. <br /> to REGULAR UNLEADED 3 DIESEL 6 AVIATION GAS <br /> A. 1 MOTOR VEHICLE FUEL ❑ 4 OIL g. � C. ❑ ❑ <br /> ❑ 2 PETROLEUM ❑ 80 EMPTY 1 PRODUCT ❑ ib PREMIUM UNLEADED ❑ 4 GASAHOL ❑ 7 METHANOL <br /> ❑ 1c MIOGRADE UNLEADED E::] 5 JET FUEL F-] 8 M85 <br /> E:] 3 CHEMICAL PRODUCT ❑ 95 UNKNOWN ❑ 2 WASTE ❑ 2 LEADED ❑ 99 OTHER(DESCRIBE IN ITEM D.BELOW) <br /> D. IF(A.1)IS NOT MARKED, ENTER NAME OF SUBSTANCE STORED C.A.S.#: <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOXES A.B.AND C.AND ALL THAT APPLIES IN BOX D AND E <br /> A. TYPE OF ❑ DOUBLE WALL ❑ 3 SINGLE WALL WITH EXTERIOR LINER ❑ 5 INTERNAL BLADDER SYSTEM F-] 95 UNKNOWN <br /> SYSTEM V2 SINGLE WALL ❑ 4 SINGLE WALL IN A VAULT ❑ 99 OTHER <br /> B. TANK 1 BARE STEEL ❑ 2 STAINLESS STEEL ❑ 3 FIBERGLASS ❑ 4 STEEL CLAD W/FIBERGLASS REINFORCED PLASTIC <br /> MATERIAL ❑ 5 CONCRETE ❑ 6 POLYVINYL CHLORIDE ❑ 7 ALUMINUM ❑ 8 100% METHANOL COMPATIBLE W/FRP <br /> (Primary Tank) ❑ 9 BRONZE ❑ 10 GALVANIZED STEEL ❑ 95 UNKNOWN ❑ 99 OTHER <br /> C.INTERIOR 711 RUBBER LINED ALKYD LINING ❑ 3 EPDXY LINING ❑ 4 PHENOLIC LINING <br /> LINING OR 7 5 GLASS LINING 6 UNLINED ❑ 95 KNOWN ❑ 99 OTHER <br /> COATING IS LINING MATERIAL COMPATIBLE WITH 100% METHANOL? YES NO_ <br /> D.EXTERIOR ❑ 1 POLYETHYLENE WRAP ❑ 2 COATING V95 <br /> VINYL WRAP ❑ 4 FIBERGLASS REINFORCED PLASTIC <br /> CORROSION <br /> PROTECTION ❑ 5 CATHODIC PROTECTION ❑ 91 NONE UNKNOWN ❑ 99 OTHER <br /> E.SPILL AND OVERFILL etc. SPILL CONTAINMENT STALLED(YEAR) OVERFILIIPREVENTION EQUIPMENT INSTALLED(YEAR) It <br /> DROP TUBE YES NO STRIKER PLATE YES V NO DISPENSER CONTAINMENT YES NO <br /> IV.PIPING INFORMATION CIRCLE A IF ABOVE GROUND OR U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A. SYSTEM TYPE A U 1 SUCTION A rU 3 PRESSURE A U 3 GRAVITY A U 4 FLEXIBLE PIPING A U 99 OTHER <br /> B. CONSTRUCTION U SINGLE WALL A U 2 DOUBLE WALL A U 3 LINED TRENCH A U 95 UNKNOWN A U 99 OTHER <br /> C. MATERIAL AND A U 1 BARE STEEL A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC)A U 4 FIBERGLASS PIPE <br /> CORROSION A U 5 ALUMINUM A U 6 CONCRETE A U 7 STE W/COATING A U 8 100% METHANOL COMPATIBLE W/FRP <br /> PROTECTION A U GALVANIZED STEEL A U 10 CATHODIC PROTECTION U 5 UNKNOWN A U 99 OTHER <br /> 1 MECHANICAL UHT <br /> NE LEAK 2 LINE TIGNESS 3 CONTINUOUS INTERSTITIAL4 ELECTRONIC UNE 5 AUTOMATIC PUMP <br /> D. LEAK DETECTION OETECTOR TESTING MONITORING ❑ LEAK DETECTOR E] SHUTDOWN ❑ 99 OTHER <br /> V.TANK LEAK DETECTION <br /> ❑ i VISUAL CHECK ❑ MANUAL RECONCILIATION INVENTORY ❑ 3 MAONNIITORING O 4 GAUGING IC TANK AUTOMATE] 5 MON TORINGGROUND WATER 6 ANNUAL <br /> ❑ 7 MON TORIONG J INTERSTITIAL - a SIR ❑ g TV%EKLY GAUGINGAL ❑10 MOTESTINGHLY TANK E] 95 UNKNOWN ❑99 OTHER <br /> VI.TANK CLOSURE INFORMATION(PERMANENT CLOSURE IN-PLACE) <br /> 1.ES-nMATgD DATE I T USElkjMO/DAYNR) 2.ESTIMATED QUANTITY OF 3.WAS TANK FILLED WITH YES ❑ NO <br /> SUBSTANCE REMAINING GALLONS INERT MATERIAL? <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY F*JUF,,fAPD TO THE BEST OF MY KNOWLEDGE,IS TRUE AND CORRECT <br /> TANK OWNER'S NAME DAT <br /> (PRINTED 6 SIGNATURE) NA <br /> LOCAL AGENCY USE ONLY g THESTATEI.D.NUMBER I MPOSED 0 E FOUR NUMBERS BELOW <br /> COUNTY# JURISDICTION# FACILITY# TANK# <br /> STATE I.D.4 m I I = <br /> PERMIT NUMBER PERMIT APPROVED BY/DATE PERMIT EXPIRATION DATE <br /> THIS FORM MUST BE ACCOMPANIED BY A PERMIT APPLICATION.FORM A,UNLESS A CURRENT FORM A HAS BEEN FILED. FORM C MUST BE COMPLETED FOR INSTALLATIONS.THIS FORM <br /> SHOULD BE ACCOMPANIED BY A PLOT PLA`" LE THIS FORM WITH THE LOCAL AGENCY IMPLEMENTING THE U' RGROUND STORAGE TANK REGULATIONS <br /> FORM B (6.95) <br />
The URL can be used to link to this page
Your browser does not support the video tag.