Laserfiche WebLink
SYSPEM <br />SET—UP REPORTWage2) <br />T 2:Premium_Unlead <br />L 4:FUEL ALARM <br />LEAK TEST METHOD <br />OUTPUT RELAY SETUP <br />PRODUCT CODE <br />B <br />- - - - -- - - - - -- <br />-- - - -- - - - - -- <br />THERNIAL COEFF :.000700 <br />HIGH WATER LIMIT: <br />TEST ON DATE : ALL TANK <br />LIQUID SENSOR SETUP <br />TANK DIAMETER <br />96.00 <br />JAN 1, 1996 <br />R 1:87 STP <br />TANK PROFILE <br />4 PTS <br />START TIME : DISABLED <br />TYPE: <br />FULL VOL <br />12000 <br />TEST RATE :0.20 GAL/ HR <br />STANDARD <br />72.0 INCH VOL <br />9999 <br />DURATION 2 HOURS <br />NORMALLY CLOSED <br />48.0 INCH VOL <br />6355 <br />11400 <br />CATEGORY : ANNULAR SPACE <br />24.0 INCH VOL <br />2505 <br />TST EARLY STOP:DISABLED <br />TANK 0: 2 <br />LEAK TEST REPORT FORMAT <br />FLOAT SIZE: 4.0 IN. <br />NORMAL <br />IN -TANK ALARMS <br />L 4:FUEL ALARM <br />L 4:SENSOR OUT ALARM <br />T 2:HIGH WATER ALARM <br />WATER WARNING <br />2.0 <br />- --- <br />T 2 : LOW PRODUCT ALARM <br />HIGH WATER LIMIT: <br />3.0 <br />LIQUID SENSOR SETUP <br />ISD DEGRD PRES FAIL <br />TANK TEST NOTIFY: OFF <br />-- - - -- - - - - -_ <br />LIQUID SEIVSOkALI1S <br />MAX OR LABEL VOL: <br />12000 <br />ALL:GROSS COLLECT FAIL <br />L 2:FUEL ALARM <br />OVERFILL LIMIT <br />90% <br />L 1:87 ANNULAR <br />L 2:SENSOR OUT ALARM <br />HIGH PRODUCT <br />10800 <br />95% <br />DUAL POINT HYDROSTATIC <br />L 2:SHORT ALARM <br />11400 <br />CATEGORY : ANNULAR SPACE <br />ISD SITE ALARMS <br />DELIVERY LIMIT <br />10% <br />ISD GROSS FRES FAIL <br />1200 <br />ISD DEGRD FRES FAIL <br />L 2:87 SUMP <br />ISD VAPOR LEAK FAIL <br />LOW PRODUCT <br />LEAK ALARM LIMIT: <br />637 <br />99 <br />TRI-STATE (SINGLE FLOAT) . <br />ISD HOSE ALAkr1S <br />SUDDEN LOSS LIMIT: <br />25 <br />CATEGORY STP SUMP <br />ALL:GROSS COLLECT FAIL <br />TANK TILT <br />1.00 <br />ALL:DEGRD COLLECT FAIL <br />PROBE OFFSET <br />0.00 <br />L 3:91 ANNULAR <br />ALL:FLOW COLLECT FAIL <br />DUAL POINT HYDROSTATIC. <br />STP <br />SIPHON MANIFOLDED TANKS <br />CATEGORY : ANNULAR SPACE <br />TYPE: <br />TO: NONE <br />STANDARD <br />LINE MANIFOLDED TANKS <br />NORMALLY CLOSED <br />TO: NONE <br />L 4:91 SUMP <br />TRI-STATE (SINGLE FLOAT) <br />TANK 0: 1 <br />LEAK MIN PERIODIC: <br />0% <br />CATEGORY : STP SUMP <br />0 <br />IN -TANK ALARMS <br />PERIODIC TEST TYPE <br />T 1:HIGH WATER ALARM <br />STANDARD <br />T 1:LOW PRODUCT ALARM <br />PERIODIC TEST FAIL <br />LIQUID SENSOR ALMS <br />ALARM DISABLED <br />L 4:FUEL ALARM <br />L 4:SENSOR OUT ALARM <br />GROSS TEST FAIL <br />L 4:SHORT ALARM <br />ALARM DISABLED <br />ISD SITE ALARMS <br />PER TEST AVERAGING: OFF <br />ISD GROSS FRES FAIL <br />ISD DEGRD PRES FAIL <br />TANK TEST NOTIFY: OFF <br />ISD VAPOR LEAK FAIL <br />TNK TST SIPHON BREAKOFF <br />ISD HOSE ALARMS <br />ALL:GROSS COLLECT FAIL <br />DELIVERY DELAY 5 MIN <br />ALL:DEGRD COLLECT FAIL <br />PUMP THRESHOLD 10.00% <br />ALL:FLOW COLLECT FAIL <br />0 2012 Walton Engineering, Inc. <br />