My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2006-2013
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
F
>
FREMONT
>
2285
>
2300 - Underground Storage Tank Program
>
PR0231111
>
COMPLIANCE INFO_2006-2013
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/26/2021 9:09:52 AM
Creation date
6/23/2020 6:43:01 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2006-2013
RECORD_ID
PR0231111
PE
2361
FACILITY_ID
FA0001659
FACILITY_NAME
QUIK STOP MARKET #7039
STREET_NUMBER
2285
Direction
E
STREET_NAME
FREMONT
STREET_TYPE
ST
City
STOCKTON
Zip
95205
APN
141-214-03
CURRENT_STATUS
01
SITE_LOCATION
2285 E FREMONT ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231111_2285 E FREMONT_2006-2013.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
466
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
The following represents minimum sampling criterion required for closure compliance. Soil samples collected shall be <br />representative of native soils beneath the tank's invert (tank's bottom) at a collection depth not to exceed 2 - 4 feet. If <br />contamination is documented during closure, an Unauthorized Release Notification must be completed and submitted within five (5) <br />working days pursuant to California Health & Safety Code, Section 25295. <br />DISPENSER PIPING AND STOCKPILE SAMPLES <br />Tri -Regional Recommendations <br />Appendix A <br />TABLE #2 RECOMMENDED MINIMUM VERIFICATION ANALYSES <br />FOR UNDERGROUND STORAGE TANK INVESTIGATIONS <br />Tanksemi- <br />BTEX VOCs Title <br />Gasoline Diesel by by VOCs Oil & PCBs Total 22 <br />Required Metals <br />80218 82608 <br />Samples Contents by 8015M by by Grease by Lead by <br />Carbon <br />( a or 82608 8015M or (1) 8 (2;C by 1664A 8082 7421 (3) <br />Range) � 82608 <br />Unknown Fuel X X X X <br />C4 -C36 <br />Gasoline (C4 -C20) X X X <br />Diesel (C10 -C36) X X X <br />Jet Fuel/Kerosene X X <br />C9 -C20 <br />HeatinC O2) X <br />Stoddard Solvent <br />(C8 -C20) X X a <br />Non -Chlorinated <br />Chlorinated X X <br />Solvents <br />Waste Oil or X X X X X X X <br />Unknown Contents <br />Notes: <br />1. EPA Method 8260B analyses must include all analytes listed in the method plus fuel oxygenates methyl -tertiary -butyl ether <br />(MTBE), diisopropyl ether (DIPE), ethyl -tertiary -butyl ether (EtBE), tertiary -amyl -methyl ether (TAME), tertiary -butanol (TBA), <br />methanol and ethanol and fuel additives 1,2-dichloroethane (1,2 -DCA) and ethylene dibromide (EDB or 1,2-dibromoethane). <br />2. If pentachlorophenol (PCP) is identified, analyze the soil and/or water sample for dioxins and furans by EPA Method 8290 <br />and pesticides by EPA Method 8081A. <br />3. Method 6010B may be used for all the following metals, for which individual AA methods are required: Antimony & Arsenic <br />by 7062, Cadmium by 7131A, Lead by 7421, Mercury by 7471A, Nickel by 7521, Selenium by 7742, and Thallium by 7841. <br />4. Non-proprietary, performance based analytical methods may be used with approval of Regional Board staff. <br />Revised 8/3/07 <br />3 <br />DISPENSER SAMPLES <br />1 Sample beneath each dispenser <br />PIPING SOIL SAMPLES <br />1 Sample every 20 lineal feet <br />DISPENSER & PIPING STOCKPILE SAMPLES <br />2 Samples every 50 cubic yards <br />Tri -Regional Recommendations <br />Appendix A <br />TABLE #2 RECOMMENDED MINIMUM VERIFICATION ANALYSES <br />FOR UNDERGROUND STORAGE TANK INVESTIGATIONS <br />Tanksemi- <br />BTEX VOCs Title <br />Gasoline Diesel by by VOCs Oil & PCBs Total 22 <br />Required Metals <br />80218 82608 <br />Samples Contents by 8015M by by Grease by Lead by <br />Carbon <br />( a or 82608 8015M or (1) 8 (2;C by 1664A 8082 7421 (3) <br />Range) � 82608 <br />Unknown Fuel X X X X <br />C4 -C36 <br />Gasoline (C4 -C20) X X X <br />Diesel (C10 -C36) X X X <br />Jet Fuel/Kerosene X X <br />C9 -C20 <br />HeatinC O2) X <br />Stoddard Solvent <br />(C8 -C20) X X a <br />Non -Chlorinated <br />Chlorinated X X <br />Solvents <br />Waste Oil or X X X X X X X <br />Unknown Contents <br />Notes: <br />1. EPA Method 8260B analyses must include all analytes listed in the method plus fuel oxygenates methyl -tertiary -butyl ether <br />(MTBE), diisopropyl ether (DIPE), ethyl -tertiary -butyl ether (EtBE), tertiary -amyl -methyl ether (TAME), tertiary -butanol (TBA), <br />methanol and ethanol and fuel additives 1,2-dichloroethane (1,2 -DCA) and ethylene dibromide (EDB or 1,2-dibromoethane). <br />2. If pentachlorophenol (PCP) is identified, analyze the soil and/or water sample for dioxins and furans by EPA Method 8290 <br />and pesticides by EPA Method 8081A. <br />3. Method 6010B may be used for all the following metals, for which individual AA methods are required: Antimony & Arsenic <br />by 7062, Cadmium by 7131A, Lead by 7421, Mercury by 7471A, Nickel by 7521, Selenium by 7742, and Thallium by 7841. <br />4. Non-proprietary, performance based analytical methods may be used with approval of Regional Board staff. <br />Revised 8/3/07 <br />3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.