My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1996-2004
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
1210
>
2300 - Underground Storage Tank Program
>
PR0231125
>
COMPLIANCE INFO_1996-2004
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/24/2024 11:40:15 AM
Creation date
6/23/2020 6:43:31 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1996-2004
RECORD_ID
PR0231125
PE
2361
FACILITY_ID
FA0003730
FACILITY_NAME
TIWANA GAS & FOOD
STREET_NUMBER
1210
Direction
E
STREET_NAME
HAMMER
STREET_TYPE
LN
City
STOCKTON
Zip
95210
APN
09403012
CURRENT_STATUS
01
SITE_LOCATION
1210 E HAMMER LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231125_1210 E HAMMER_1996-2004.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
406
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
iNo'vi®u�►L TANK iNFORnnarioN AND TEST RESULTS <br /> TEST DATE:08/02/04 8900 SHOAL CREEK,BUILDING 200 WORK ORDER NUMBER2231836 <br /> CLIENT:VALERO AUSTIN,TEXAS 78757(512)451-6334 SITE:ULTRAMAR 641 <br /> offinuMMEMENEEMSEEM <br /> Tank ID: #2 2 Tank manifolded: No Bottom to top fill in inches: 182.0 <br /> Product: PLUS Vent manifolded: YES Bottom to grade in inches: 199.0 <br /> Capacity in gallons: 10,118 Vapor recovery manifolded: YES Fill pipe length in inches: 54.0 <br /> Diameter in inches: 128.00 Overfill protection: YES Fill pipe diameter in inches: 4.0 <br /> Length in inches: 184 Overspill protection: YES Stage I vapor recovery: DUAL <br /> Material: DW STEEL Installed: ATG Stage 11 vapor recovery: ASSIST <br /> CP installed on: <br /> COMMENTS <br /> Dipped Water Level: Start(in) End(in) New/passed Failed/replaced New/passed Failed/replaced <br /> Dipped Product Level: L.D.#1 L.D.#1 L.D.#2 L.D.#2 <br /> Probe Water Level: Make: RED JACKET <br /> Ingress Detected: Water Bubble Ullage Model: Fx1V <br /> Test time: S/N: 406020193 <br /> Inclinometer reading: Open time in sec: 2.00 <br /> Holding psi: 24 <br /> VacuTect Test Type: NOT Resiliency psi: <br /> los NOT <br /> VacuTect Probe Entry Point: TESTED est leak rate ml/m: 189.0 TESTED <br /> Pressure Set Point: Metering psi: 14 <br /> Tank water level in inches: Calib.leak in gph: 3.00 <br /> Water table depth in inches: Results: PASS <br /> Determined by(method): <br /> Result: <br /> COMMENTS <br /> COMMENTS <br /> Material: DW FIBERG <br /> Diameter(in): 2.0 <br /> Length(ft): 100.0 <br /> Test psi: 5o <br /> Bleedback cc: 140 <br /> Test time(min): 30 NOT NOT NOT <br /> Start time: 11:50 TESTED TESTED TESTED <br /> End time: 12:20 <br /> Final gph: 0.000 <br /> Result: PASS <br /> Pump type: PRESSURE <br /> Pump make: RED JACKET <br /> COMMENTS Impact Valves Operational: YES <br /> Printed 08/09/2004 07:46 <br />
The URL can be used to link to this page
Your browser does not support the video tag.