My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2011-2013
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
1210
>
2300 - Underground Storage Tank Program
>
PR0231125
>
COMPLIANCE INFO_2011-2013
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/8/2021 3:02:45 PM
Creation date
6/23/2020 6:43:31 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2011-2013
RECORD_ID
PR0231125
PE
2361
FACILITY_ID
FA0003730
FACILITY_NAME
TIWANA GAS & FOOD
STREET_NUMBER
1210
Direction
E
STREET_NAME
HAMMER
STREET_TYPE
LN
City
STOCKTON
Zip
95210
APN
09403012
CURRENT_STATUS
01
SITE_LOCATION
1210 E HAMMER LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231125_1210 E HAMMER_2011-2013.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
318
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB, January 2002 <br />E <br />E <br />Page _1_ of 2_ <br />4. TANK ANNULAR TESTING <br />Test Method Developed By: Tank Manufacturer X Industry Standard Professional Engineer <br />Other (Spec) <br />Test Method Used: Pressure X Vacuum Hydrostatic <br />Other (Spec) <br />Test Equipment Used: Vacuum Gauge Equipment Resolution: 1" <br />TTankxempt From Testing?' <br />Tank # 87 -Oct <br />Yes X No <br />Tank # <br />Yes <br />77Tank <br />No <br /># <br />Yes No <br />Tank # <br />Yes <br />No <br />acity: <br />12,000 <br />Tank Material: <br />Steel <br />Tank Manufacturer: <br />Trusco <br />Product Stored: <br />Regular Unleaded <br />Wait time between applying <br />pressure/vacuum/water and <br />starting test: <br />30 min <br />Test Start Time: <br />10:00 am <br />Initial Reading (RI): <br />20" <br />Test End Time: <br />11:00 am <br />Final Reading (RF): <br />22" <br />Test Duration: <br />1 Hour <br />Change in Reading (RF-&): <br />2" Vacuum Increase <br />Pass/Fail Threshold or Criteria: <br />Teat Result: <br />XPass - ❑ Fail <br />0 'Pan <br />❑ Fait <br />❑ Pan ❑ Fail <br />❑ Pus <br />❑]Fail <br />Was sensor removed for testing? <br />X Yes NA No <br />Yes <br />No NA <br />Yes No NA <br />Yes <br />No NA <br />Was sensor properly replaced and <br />verified functional after testin ? <br />X Yes No <br />NA <br />Yes <br />No NA <br />Yes No NA <br />Yes <br />No NA <br />Comments — (include information on repairs made prior to testinx, and recommended follow-up for failed tests <br />Test was required as part of repair permit issued by San Joaquin Co. Heath. Initial call was for repairs to <br />Secondary containment sump reducer that had failed over time. Secondary containment test is required <br />Anytime concrete is broken to make repairs to a tank. Initial secondary test failed, we applied 2psi pressure <br />To secondary annular space and located leak at the Regular fill riser bungfftberglass containment joint. <br />Vacuum was applied to secondary annular space and sealant was applied to the failed joint. <br />' Secondary containment systems where the continuous monitoring automatically monitors loth the primary and secondary <br />containment, such as systems that are hydrostatically monitored or under constant vacuum, are exempt from periodic containment <br />testing. (California Code of Regulations, Title 23, Section 2637(a)(6)) <br />
The URL can be used to link to this page
Your browser does not support the video tag.